Relationships among multifocal electroretinogram amplitude, visual field sensitivity, and SD-OCT receptor layer thicknesses in patients with retinitis pigmentosa.

机构信息

Retina Foundation of the Southwest, Dallas, Texas, USA.

出版信息

Invest Ophthalmol Vis Sci. 2012 Feb 21;53(2):833-40. doi: 10.1167/iovs.11-8410. Print 2012 Feb.

Abstract

PURPOSE

To compare local functional measures, the multifocal electroretinogram (mfERG) and visual field sensitivity, with a local structural measure, spectral domain (SD) optical coherence tomography (OCT), of receptor damage in patients with retinitis pigmentosa (RP).

METHODS

MfERGs, visual fields, and SD-OCT scans were obtained from 10 patients with RP, ranging in age from 23 to 59 years. Average amplitudes, average linear sensitivities, and average layer thicknesses were measured from within the central 3° and from three concentric annuli located between 3° and 8°, 8° and 15°, and 15° and 24°. A computer program aided manual segmentation and calculated OCT thickness in the scans.

RESULTS

Within each patient with RP, mfERG amplitude for each circle/annulus was highly correlated with corresponding layer thicknesses in the outer retina (r = 0.88 to 0.99), but not at all correlated with thickness of the inner nuclear layer or total retina. Across all ring eccentricities, relative mfERG amplitude and relative visual field sensitivity were correlated with relative SD-OCT outer retinal thickness.

CONCLUSIONS

In patients with RP, preserved cone photoreceptor function measured by mfERG amplitude and visual field sensitivity correlate well with the remaining thickness of the photoreceptor layer. All three measures show comparable relative loss beyond 3° eccentricity. In the fovea, SD-OCT outer retina thickness showed less relative loss than either mfERG or visual field sensitivity.

摘要

目的

比较局部功能测量(多焦视网膜电图 [mfERG] 和视野敏感度)与局部结构测量(谱域 [SD] 光学相干断层扫描 [OCT])在视锥细胞感受器损伤患者中的视网膜色素变性(RP)。

方法

从年龄在 23 至 59 岁的 10 名 RP 患者中获得 mfERG、视野和 SD-OCT 扫描。从中央 3°范围内以及位于 3°至 8°、8°至 15°和 15°至 24°之间的三个同心环内测量平均振幅、平均线性敏感度和平均层厚度。计算机程序辅助手动分割并计算扫描中的 OCT 厚度。

结果

在每个 RP 患者中,每个环/环的 mfERG 振幅与外视网膜的相应层厚度高度相关(r = 0.88 至 0.99),但与内核层或总视网膜的厚度无关。在所有环偏心度中,相对 mfERG 振幅和相对视野敏感度与相对 SD-OCT 外视网膜厚度相关。

结论

在 RP 患者中,mfERG 振幅和视野敏感度测量的保留的视锥细胞感光功能与感光细胞层的剩余厚度密切相关。所有三种测量方法在 3°偏心度之外都显示出可比的相对损失。在中央凹处,SD-OCT 外视网膜厚度的相对损失小于 mfERG 或视野敏感度。