Dammann H G, Dreyer M, Kangah R, Wolf N
Krankenhaus Bethanien, Hamburg, FRG.
Dig Dis. 1990;8 Suppl 1:3-9. doi: 10.1159/000171273.
The most often used methods for the measurement of intragastric acidity are repeated mostly hourly aspirations of gastric contents or continuous pH measuring with an electrode. Intragastric pH, volume of aspirated gastric juice and total acid secretion have been tested over relatively short periods of time (2-12 h) and through an entire 24-hour period. Nearly every clinical antiulcer drug which neutralizes acidity or inhibits acid secretion has been investigated with this method. pH monitoring with the gastric aspiration procedure is a reliable and reproducible method. There is a remarkable global agreement in the results. While pH electrodes provide an alternative means of measuring pH, they have the disadvantage of not allowing measurement of volume and/or acid secretion.
测量胃内酸度最常用的方法主要是每小时重复抽吸胃内容物,或用电极连续测量pH值。胃内pH值、抽吸胃液的体积和总酸分泌量已在相对较短的时间段(2 - 12小时)以及整个24小时期间进行了测试。几乎每一种中和酸度或抑制酸分泌的临床抗溃疡药物都用这种方法进行了研究。通过胃抽吸程序进行pH监测是一种可靠且可重复的方法。结果在全球范围内有着显著的一致性。虽然pH电极提供了另一种测量pH值的方法,但它们的缺点是无法测量体积和/或酸分泌量。