Balbis Sonia, Meloni Teodoro, Tofani Santi, Zenone Flora, Nucera Daniele, Guiot Caterina
Neuroscience Department, University of Torino, Torino, Italy.
J Clin Ultrasound. 2012 Mar-Apr;40(3):167-73. doi: 10.1002/jcu.21897. Epub 2012 Feb 22.
Periodic quality control (QC) for ultrasound scanners checks their overall performance, reducing the risk of inaccurate diagnoses. Data from routine annual QC activity were analyzed to optimize the scheduling and the criteria of further QC programs. Among all the ultrasound scanners (68 transducers) in use at the Regional Medical Department of the Aosta Valley, which are currently tested, 48.6% showed problems, mainly (35.3%) related to defects detectable by physical and mechanical inspection. Nearly two-thirds of these problems impacted QC parameters. Failures were significantly related to the workload and to the "technological level" of the equipment. QC scheduling should therefore include a daily/weekly physical inspection in addition to a more complete, objective and software algorithms-based test, the frequency of which should be tailored on the basis of the equipment characteristics. © 2012 Wiley Periodicals, Inc. J Clin Ultrasound, 2012.
超声扫描仪的定期质量控制(QC)可检查其整体性能,降低诊断不准确的风险。对常规年度QC活动的数据进行分析,以优化进一步QC计划的安排和标准。在瓦莱达奥斯塔地区医疗部门正在使用的所有超声扫描仪(68个换能器)中,目前接受测试的设备有48.6%出现问题,主要问题(35.3%)与通过物理和机械检查可检测到的缺陷有关。这些问题中近三分之二影响了QC参数。故障与工作量和设备的“技术水平”显著相关。因此,QC计划除了进行更全面、客观且基于软件算法的测试外,还应包括每日/每周的物理检查,其频率应根据设备特性进行调整。© 2012威利期刊公司。《临床超声杂志》,2012年。