Suppr超能文献

数字化模板的准确性:短柄全髋关节置换术与传统全髋关节置换术的比较。

The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty.

机构信息

Department of Orthopaedic Surgery, Campus Grosshadern, University Hospital of Munich, LMU, Munich, Germany.

出版信息

Int Orthop. 2012 Sep;36(9):1767-72. doi: 10.1007/s00264-012-1532-7. Epub 2012 Apr 4.

Abstract

PURPOSE

Selection of the correct femoral stem size is crucial in total hip arthroplasty for an uncomplicated implantation and good initial stability. Pre-operative templating has been shown to be a valuable tool in predicting the correct implant size. For short-stem total hip arthroplasty (SHA), which recently is increasingly used, it is unknown if templating can be performed as reliable as conventional total hip arthroplasty (THA).

METHODS

A total of 100 hip arthroplasties, 50 with SHA and 50 with THA, were templated by four orthopaedic surgeons each. The surgeons had different levels of professional experience and performed a digital template of the acetabular and femoral component on the pre-operative radiographs. The results were compared with the truly inserted implant size.

RESULTS

For the femoral stems the average percentage of agreement (± 1 size) was 89.0 % in SHA and 88.5 % in THA. There was no significant difference among surgeons in the accuracy of templating the correct stem size and no significant difference between templating SHA and THA. For the acetabular component the average percentage of agreement (± 1 size) was 75.8 %. However, the more experienced surgeons showed a significant higher accuracy for templating the correct cup size than the less experienced surgeons.

CONCLUSION

Digital templating of SHA can predict the stem sizes as accurately as conventional THA. Therefore digital templating is also recommendable for SHA, as it helps to predict the implant size prior to surgery and thereby might help to avoid complications.

摘要

目的

在全髋关节置换术中,选择正确的股骨柄尺寸对于简化植入和初始稳定性至关重要。术前模板制作已被证明是预测正确植入物尺寸的一种有价值的工具。对于最近越来越多地使用的短柄全髋关节置换术(SHA),尚不清楚模板制作是否可以像传统全髋关节置换术(THA)一样可靠。

方法

共有 100 例髋关节置换术,50 例行 SHA,50 例行 THA,由四位骨科医生每人进行模板制作。这些医生具有不同水平的专业经验,并在术前 X 光片上对髋臼和股骨组件进行了数字模板制作。结果与实际植入的植入物尺寸进行了比较。

结果

对于股骨柄,SHA 的平均一致性百分比(±1 个尺寸)为 89.0%,THA 为 88.5%。在正确模板制作股骨柄尺寸的准确性方面,医生之间没有显著差异,也没有在 SHA 和 THA 之间进行模板制作方面存在显著差异。对于髋臼组件,平均一致性百分比(±1 个尺寸)为 75.8%。然而,经验丰富的医生在正确模板制作髋臼尺寸方面的准确性明显高于经验不足的医生。

结论

SHA 的数字模板制作可以像传统 THA 一样准确地预测柄尺寸。因此,数字模板制作也推荐用于 SHA,因为它可以帮助在手术前预测植入物尺寸,从而可能有助于避免并发症。

相似文献

3
The accuracy of digital templating in uncemented total hip arthroplasty.非骨水泥型全髋关节置换术中数字模板的准确性。
Arch Orthop Trauma Surg. 2019 Feb;139(2):263-268. doi: 10.1007/s00402-018-3080-0. Epub 2018 Dec 6.

引用本文的文献

本文引用的文献

6
Hip abductor muscle strength after total hip arthroplasty with short stems.全髋关节置换术后短柄对髋关节外展肌肌力的影响。
Arch Orthop Trauma Surg. 2011 Dec;131(12):1723-9. doi: 10.1007/s00402-011-1350-1. Epub 2011 Jul 8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验