A new ultrafiltration method for measuring serum free thyroxine (FT4) is presented. The method makes use of disposable ultrafiltration devices, which were selected on grounds of their ability to produce protein-free serum ultrafiltrates necessary for accurate determination of FT4. Ultrafiltrate thyroxine was measured by radio-immunoassay. As measured by this method, the mean serum FT4 concentration in reference subjects (n = 17) was 25.4 pmol/l (SD 7.8). Two patient groups were studied: hyperthyroid (n = 20, mean serum FT4 138 pmol/l, SD 69) and hypothyroid (n = 18, mean serum FT4 14.8 pmol/l, SD 6.5). These results were compared with serum FT4 concentrations, as measured by an ultrafiltration method based on the use of dialysis-tubing bags (r = 0.97), and by an equilibrium dialysis method (r = 0.95). The mean level of FT4, as measured by the ultrafiltration methodologies, was about twice as high as that measured by equilibrium dialysis. This new FT4 method is more practical than earlier ultrafiltration methods and, theoretically, analytically more accurate than equilibrium dialysis methods.

摘要

本文介绍了一种测量血清游离甲状腺素(FT4)的新型超滤方法。该方法使用一次性超滤装置,这些装置是基于其能够产生准确测定FT4所需的无蛋白血清超滤液的能力而选择的。通过放射免疫测定法测量超滤液中的甲状腺素。用该方法测量,参考受试者(n = 17)的平均血清FT4浓度为25.4 pmol/l(标准差7.8)。研究了两组患者:甲状腺功能亢进组(n = 20,平均血清FT4 138 pmol/l,标准差69)和甲状腺功能减退组(n = 18,平均血清FT4 14.8 pmol/l,标准差6.5)。将这些结果与通过基于使用透析管袋的超滤方法测量的血清FT4浓度(r = 0.97)以及通过平衡透析法测量的血清FT4浓度(r = 0.95)进行比较。通过超滤方法测量的FT4平均水平约为通过平衡透析法测量的水平的两倍。这种新的FT4方法比早期的超滤方法更实用,并且从理论上讲,在分析上比平衡透析方法更准确。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验