Suppr超能文献

影像学与电子法测定根管工作长度

Radiographic versus electronic root canal working length determination.

作者信息

Kqiku Lumnije, Städtler Peter

机构信息

Division of Preventive and Operative Dentistry, Endodontics, Pedodontics, and Minimally Invasive Dentistry, University Clinic of Dentistry and Maxillofacial Surgery, Medical University Graz, Austria.

出版信息

Indian J Dent Res. 2011 Nov-Dec;22(6):777-80. doi: 10.4103/0970-9290.94666.

Abstract

PURPOSE

The aim of this ex vivo study was to compare the accuracy of radiographic and electronic root canal length determination methods, compared with actual root canal length obtained with stereomicroscope.

MATERIALS AND METHODS

Thirty extracted single-rooted permanent teeth were used for this study. After access preparation, actual length (AL) of the root canal were determined for each tooth by inserting a #15 file until the tip of the file was visible at the apical foramen under a stereomicroscope. The radiographic working length determination was determined with a digital radiographic system and for the electronic measurement all teeth were embedded in an alginate model to test apex locator in-vitro. Data was analyzed using the descriptive statistic and intraclass correlation coefficient.

RESULTS

No significant difference was found between the radiographic and electronic root canal working length determination (P>0.05). The percentage of electronic measurements within ± 0.5 mm to the apical constriction was 93.34% and 90% for radiographic methods within ± 0.5 mm of all cases compared with AL.

CONCLUSIONS

The present ex vivo study showed that electronic root canal working length determination is not superior to radiographic methods. Both methods provided a good performance in determining the root canal working length.

摘要

目的

本体外研究的目的是将放射影像学和电子根管长度测定方法的准确性与通过体视显微镜获得的实际根管长度进行比较。

材料与方法

本研究使用了30颗拔除的单根恒牙。开髓预备后,通过插入一根#15锉直至锉尖在体视显微镜下可见根尖孔,来确定每颗牙齿根管的实际长度(AL)。使用数字放射成像系统确定放射影像学工作长度,对于电子测量,将所有牙齿嵌入藻酸盐模型中以在体外测试根尖定位仪。使用描述性统计和组内相关系数分析数据。

结果

放射影像学和电子根管工作长度测定之间未发现显著差异(P>0.05)。与AL相比,所有病例中电子测量在距根尖狭窄±0.5mm范围内的百分比为93.34%,放射影像学方法在±0.5mm范围内的百分比为90%。

结论

目前的体外研究表明,电子根管工作长度测定并不优于放射影像学方法。两种方法在确定根管工作长度方面均表现良好。