Department of Operative Dentistry, Dental Materials and Endodontics Bauru Dental School, University of São Paulo, Bauru, Brazil.
Int Endod J. 2012 Oct;45(10):915-20. doi: 10.1111/j.1365-2591.2012.02049.x. Epub 2012 Apr 9.
To analyse several physicochemical properties of AH Plus (Dentsply DeTrey, Konstanz, Germany), including setting time, flow, radiopacity and the degree of conversion (DC); and to correlate the results with the source of the material: from the beginning, middle or end of the tubes in which they were supplied.
Three experimental groups were established for each property investigated. Group 1 corresponded to material taken from the beginning of tubes A and B; Group 2 corresponded to material taken from the middle of each tube; and group 3 corresponded to that from the end of each tube. The setting time, flow and radiopacity were studied according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. DC was determined from infrared spectra, which were recorded at 1-h intervals for the first 6 h; then, at 2-h intervals for the next 14 h; then, at 24 and 30 h. Data were analysed statistically by analysis of variance (anova), Tukey-Kramer, Kruskal-Wallis and Dunn tests, with a significance level of 5%.
Group 1 had a significantly longer setting time (2303 ± 1058 min) (P < 0.05). Group 3 had the lowest flowability (30.0 ± 0.7 mm) and the highest radiopacity (14.85 ± 1.8 mm Al) (P < 0.05). No differences were found for the DC test (P > 0.05).
The results suggest that segregation occurs between the organic and inorganic components of AH Plus sealer, thereby changing the setting time, flow and radiopacity.
分析 AH Plus(德国登士柏迪特瑞公司)的若干理化性能,包括凝固时间、流动性、射线阻射性和转化率(DC);并将结果与材料的来源相关联:材料取自供应的管的起始端、中间或末端。
为每种研究的特性建立了三个实验组。第 1 组对应于取自管 A 和 B 起始端的材料;第 2 组对应于取自每个管中间的材料;第 3 组对应于取自每个管末端的材料。根据美国国家标准协会/美国牙科协会(ANSI/ADA)规范 57 研究凝固时间、流动性和射线阻射性。DC 从红外光谱确定,在最初的 6 小时内每 1 小时记录一次;然后,在接下来的 14 小时内每 2 小时记录一次;然后,在 24 和 30 小时记录。数据通过方差分析(anova)、Tukey-Kramer、Kruskal-Wallis 和 Dunn 检验进行统计分析,显著性水平为 5%。
第 1 组的凝固时间明显较长(2303 ± 1058 分钟)(P < 0.05)。第 3 组的流动性最低(30.0 ± 0.7 毫米),射线阻射性最高(14.85 ± 1.8 毫米 Al)(P < 0.05)。对于 DC 测试,没有发现差异(P > 0.05)。
结果表明,AH Plus 密封剂的有机和无机成分之间发生了分离,从而改变了凝固时间、流动性和射线阻射性。