Abstract

Study Design/Objective. A single-centre, prospective, non-comparative study of 25 patients to evaluate the performance and safety of the Memory Metal Minimal Access Cage (MAC) in Lumbar Interbody Fusion. Summary of Background Data. Interbody fusion cages in general are designed to withstand high axial loads and in the meantime to allow ingrowth of new bone for bony fusion. In many cages the contact area with the endplate is rather large leaving a relatively small contact area for the bone graft with the adjacent host bone. MAC is constructed from the memory metal Nitinol and builds on the concept of sufficient axial support in combination with a large contact area of the graft facilitating bony ingrowth and ease in minimal access implantation due to its high deformability. Methods. Twenty five subjects with a primary diagnosis of disabling back and radicular leg pain from a single level degenerative lumbar disc underwent an interbody fusion using MAC and pedicle screws. Clinical performance was evaluated prospectively over 2 years using the Oswestry Disability Index (ODI), Short Form 36 questionnaire (SF-36) and pain visual analogue scale (VAS) scores. The interbody fusion status was assessed using conventional radiographs and CT scan. Safety of the device was studied by registration of intra- and post-operative adverse effects. Results. Clinical performance improved significantly (P < .0018), CT scan confirmed solid fusion in all 25 patients at two year follow-up. In two patients migration of the cage occurred, which was resolved uneventfully by placing a larger size at the subsequent revision. Conclusions. We conclude that the Memory Metal Minimal Access Cage (MAC) resulted in 100% solid fusions in 2 years and proved to be safe, although two patients required revision surgery in order to achieve solid fusion.

摘要

研究设计/目的。一项针对25例患者的单中心、前瞻性、非对照研究,以评估记忆金属微创融合器(MAC)在腰椎椎间融合术中的性能和安全性。背景数据总结。椎间融合器一般设计用于承受高轴向负荷,同时允许新骨向内生长以实现骨融合。在许多融合器中,与终板的接触面积相当大,留给骨移植与相邻宿主骨的接触面积相对较小。MAC由记忆金属镍钛诺制成,基于足够的轴向支撑概念,结合移植物的大接触面积,促进骨向内生长,并且由于其高可变形性,便于微创植入。方法。25例因单节段退变性腰椎间盘导致严重腰背痛和神经根性腿痛的患者接受了使用MAC和椎弓根螺钉的椎间融合术。使用Oswestry功能障碍指数(ODI)、简明健康状况调查量表(SF-36)和疼痛视觉模拟量表(VAS)评分对临床性能进行了为期2年的前瞻性评估。使用传统X线片和CT扫描评估椎间融合状态。通过记录术中和术后不良反应来研究该装置的安全性。结果。临床性能显著改善(P <.0018),CT扫描证实在两年随访时所有25例患者均实现了牢固融合。有2例患者发生融合器移位,在随后的翻修手术中通过放置更大尺寸的融合器得以顺利解决。结论。我们得出结论,记忆金属微创融合器(MAC)在2年内实现了100%的牢固融合,且被证明是安全的,尽管有2例患者需要翻修手术才能实现牢固融合。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/eb6c/3332066/aad34e007612/AOP2012-898606.001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验