The objective of this study was to investigate the shear bond strength of compound made of tooth enamel, adhesive, and brackets for certain material combinations according to the DIN 13990-2 standard.
We examined a combination of the following materials on permanent bovine incisors: (1) adhesives: Light Bond™ and Phase II® (both produced by Reliance Orthodontic Products, Itasca, IL, USA), Transbond XT™ (3M Unitek, Monrovia, CA, USA), (2) brackets: Carriere®, Euro Midi Classic, Midi Low Friction (all from Ortho Organizers, Carlsbad, CA, USA). The discovery® bracket (Dentaurum, Ispringen, Germany) served as the reference. According to the DIN standard, the teeth were embedded, adhesive was applied and they were then put into storage. This was followed by shear tests in a material testing machine with the shear force acting directly on the bracket base in the occlusal-gingival direction. Finally, the Adhesive Remnant Index was determined.
We observed the greatest shear bond strength (mean value) from the combination of Carriere® and Transbond XT™ (17.4 N/mm(2)), and the lowest from the combination of Euro Midi Classic and Phase II® (12.8 N/mm(2)). There were significant differences in the various material combinations. The values obtained from the measurements of discovery® together with Transbond XT™ agreed very well with the results of previous investigations.
The combinations of brackets and adhesives investigated in this study according to DIN standard 13990-2 provided a satisfactory result for clinical use.
本研究的目的是根据DIN 13990 - 2标准,研究由牙釉质、粘合剂和托槽组成的复合材料在特定材料组合下的剪切粘结强度。
我们在恒河牛切牙上检测了以下材料的组合:(1)粘合剂:Light Bond™和Phase II®(均由美国伊利诺伊州伊塔斯卡的Reliance正畸产品公司生产),Transbond XT™(美国加利福尼亚州蒙罗维亚的3M Unitek公司生产);(2)托槽:Carriere®、Euro Midi Classic、Midi Low Friction(均来自美国加利福尼亚州卡尔斯巴德的Ortho Organizers公司)。discovery®托槽(德国伊施普林根的Dentaurum公司生产)作为对照。根据DIN标准,将牙齿嵌入,涂抹粘合剂,然后进行储存。随后在材料试验机上进行剪切试验,剪切力沿咬合 - 龈向直接作用于托槽底座。最后,测定粘结剂残留指数。
我们观察到Carriere®和Transbond XT™组合的剪切粘结强度(平均值)最大(17.4 N/mm²),Euro Midi Classic和Phase II®组合的剪切粘结强度最低(12.8 N/mm²)。不同材料组合之间存在显著差异。discovery®与Transbond XT™组合的测量值与先前研究结果非常吻合。
本研究根据DIN标准13990 - 2研究的托槽和粘合剂组合在临床应用中提供了令人满意的结果。