99mTc-白蛋白可代替 125I-白蛋白反复测定血浆容量。

99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly.

机构信息

Department of Clinical Physiology and Nuclear Medicine, Koege Hospital, Koege, Denmark. p_bonfi

出版信息

Scand J Clin Lab Invest. 2012 Oct;72(6):447-51. doi: 10.3109/00365513.2012.688856. Epub 2012 May 31.

Abstract

OBJECTIVE

Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin ((99m)Tc-HSA) with a simultaneously performed plasma volume determination with iodine-labeled human serum albumin ((125)I-HSA).

MATERIALS AND METHODS

In 15 healthy volunteers, simultaneous plasma volume measurements with (99m)Tc-HSA and (125)I-HSA were performed after ½ hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation.

RESULTS

The mean difference (bias) between plasma volume measured with (125)I-albumin and (99m)Tc-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias ±1.96 SD) ranging from -181-196 ml (-2.3-2.5 ml/kg). The tracer disappearance rate was significantly higher with (99m)Tc-albumin (-23.1±7.1%/h) than with (125)I-albumin (-6.7±3.6%/h) (p <0.001).

CONCLUSION

This study demonstrates that (99m)Tc-HSA can replace (125)I-HSA for single measurements of plasma volume in healthy volunteers. It needs to be emphasized however, that repeated blood sampling for 1/2 hour after injection of the tracer is required to correct for the disappearance of (99m)Tc and (99m)Tc-HSA from the circulation.

摘要

目的

血浆容量评估在几种疾病中可能很重要。本研究的目的是比较锝标记人血清白蛋白((99m)Tc-HSA)与同时进行的碘标记人血清白蛋白((125)I-HSA)的血浆容量测量的可靠性。

材料和方法

在 15 名健康志愿者中,在仰卧位后半小时内同时进行 (99m)Tc-HSA 和 (125)I-HSA 的血浆容量测量。在注射后 10、15、20 和 30 分钟采集血样,以便从血浆计数准确回溯到时间零点,以校正同位素从循环中的泄漏,从而准确测量血浆容量。

结果

用 (125)I-白蛋白和 (99m)Tc-白蛋白测量的血浆容量之间的平均差异(偏差)为 8ml(0.1ml/kg),一致性界限(偏差±1.96 SD)范围为-181-196ml(-2.3-2.5ml/kg)。(99m)Tc-白蛋白的示踪剂清除率明显高于 (125)I-白蛋白(-23.1±7.1%/h)(p<0.001)。

结论

本研究表明,(99m)Tc-HSA 可以替代 (125)I-HSA 用于健康志愿者的单次血浆容量测量。然而,需要强调的是,在注射示踪剂后需要进行 1/2 小时的重复采血,以校正循环中 (99m)Tc 和 (99m)Tc-HSA 的清除。