视网膜静脉搏动与颅内压同相,而与眼压不同相。

Retinal vein pulsation is in phase with intracranial pressure and not intraocular pressure.

机构信息

Lions Eye Institute, Centre for Ophthalmology and Visual Science, Nedlands, WA, Australia.

出版信息

Invest Ophthalmol Vis Sci. 2012 Jul 10;53(8):4676-81. doi: 10.1167/iovs.12-9837.

Abstract

PURPOSE

As efforts to noninvasively measure intracranial pressure (ICP) increase, we thought it important to investigate the timing of retinal venous pulsation in relation to the intraocular and intracranial pressure pulses.

METHODS

Neurosurgical patients undergoing continuous direct ICP monitoring had video recordings of ICP, IOP, and retinal venous pulsation waveforms taken with constant timing relative to the cardiac cycle using pulse oximetry. Video frames of the maxima and minima of these parameters, including retinal vein diameter, were identified. The times from pulse oximetry "beep" to these parameters were measured and converted into a percentage of the respective cardiac cycle.

RESULTS

A total of 338 measurements from nine subjects with a mean age of 39 years, mean ICP of 4.4 mm Hg and IOP 15.1 mm Hg were taken. Vein diameter minima occurred an insignificant 0.6% of cardiac cycle before ICP minima (P = 0.6620) and a significant 3.2% after IOP minima (P = 0.0097) and significantly later than IOP (51%) and ICP maxima (74%, all P < 0.0001). Maximum vein diameter occurred an insignificant 2.0% before IOP maxima (P = 0.2267) and was significantly different from IOP and ICP minima (P < 0.00001). Mean venous pulsation pressure between the two eyes was significantly associated with ICP (r = 0.89, P = 0.0075).

CONCLUSIONS

During pulsation, central retinal vein collapse occurs in time with IOP and ICP diastole. Venous collapse is not induced by intraocular systole. These results suggest that ICP pulse pressure dominates the timing of venous pulsation.

摘要

目的

随着非侵入性测量颅内压(ICP)的努力不断增加,我们认为研究视网膜静脉搏动与眼内压和颅内压脉冲之间的时间关系非常重要。

方法

接受连续直接 ICP 监测的神经外科患者使用脉搏血氧仪以与心动周期保持恒定时间关系记录 ICP、IOP 和视网膜静脉搏动波形的视频记录。确定这些参数(包括视网膜静脉直径)的最大值和最小值的视频帧。测量从脉搏血氧仪“哔哔”声到这些参数的时间,并将其转换为相应心动周期的百分比。

结果

共对 9 名年龄 39 岁、平均 ICP 为 4.4mmHg 和 IOP 为 15.1mmHg 的患者进行了 338 次测量。静脉直径最小值出现在 ICP 最小值之前 0.6%的心动周期中(P = 0.6620),出现在 IOP 最小值之后 3.2%的心动周期中(P = 0.0097),显著晚于 IOP(51%)和 ICP 最大值(74%,均 P < 0.0001)。最大静脉直径出现在 IOP 最大值之前 2.0%的心动周期中(P = 0.2267),与 IOP 和 ICP 最小值显著不同(P < 0.00001)。双眼静脉搏动压的平均值与 ICP 显著相关(r = 0.89,P = 0.0075)。

结论

在搏动期间,中央视网膜静脉塌陷与 IOP 和 ICP 舒张同步发生。静脉塌陷不是由眼内压收缩引起的。这些结果表明,ICP 脉冲压力主导静脉搏动的时间。