Najafipour Reza, Farivar Taghi Naserpour, Pahlevan Ali Akbar, Johari Pouran, Safdarian Farshid, Asefzadeh Mina
Cell and Molecular Research Center, Qazvin University of Medical Sciences, Qazvin, Iran.
J Glob Infect Dis. 2012 Apr;4(2):106-9. doi: 10.4103/0974-777X.96773.
Helicobacter pylori is capable of inducing systemic inflammatory reactions through immunological processes. There are several methods to identify the presence of H. pylori in clinical samples including rapid urease test (RUT), conventional polymerase chain reaction (PCR), and the Scorpion real-time PCR.
The aim of the present study is to compare the agreement rate of these tests in identifying H. pylori in tonsillar biopsy specimens collected from patients with chronic tonsillitis.
A total of 103 tonsil biopsy samples from patients with clinical signs of chronic tonsillitis were examined with RUT, PCR, and Scorpion real-time PCR. The degree of agreement between the three tests was later calculated.
There was a poor degree of agreement between RUT and PCR and also RUT and Scorpion real-time PCR (Kappa=0.269 and 0.249, respectively). In contrast with RUT, there was a strong degree of agreement between PCR and Scorpion real-time PCR (Kappa=0.970).
The presence of a strong agreement between the Scorpion real-time PCR and PCR as well as its technical advantage over the conventional PCR assay, made the Scorpion real-time PCR an appropriate laboratory test to investigate the presence of H. pylori in tonsillar biopsy specimens in patients suffering from chronic tonsillitis.
幽门螺杆菌能够通过免疫过程引发全身炎症反应。临床样本中鉴定幽门螺杆菌存在的方法有多种,包括快速尿素酶试验(RUT)、传统聚合酶链反应(PCR)和蝎形实时PCR。
本研究旨在比较这些检测方法在鉴定慢性扁桃体炎患者扁桃体活检标本中幽门螺杆菌时的符合率。
对103例有慢性扁桃体炎临床症状患者的扁桃体活检样本进行RUT、PCR和蝎形实时PCR检测。随后计算这三种检测方法之间的符合程度。
RUT与PCR以及RUT与蝎形实时PCR之间的符合程度较差(Kappa值分别为0.269和0.249)。与RUT相反,PCR与蝎形实时PCR之间有高度符合程度(Kappa值=0.970)。
蝎形实时PCR与PCR之间高度符合,以及其相对于传统PCR检测的技术优势,使得蝎形实时PCR成为检测慢性扁桃体炎患者扁桃体活检标本中幽门螺杆菌存在情况的合适实验室检测方法。