Suppr超能文献

经过短期培训后,急诊医师对多种适应证进行床旁超声检查的初始准确性。

Initial accuracy of bedside ultrasound performed by emergency physicians for multiple indications after a short training period.

机构信息

Emergency Department, Hospital Infanta Cristina, Parla, Madrid, Spain.

出版信息

Am J Emerg Med. 2012 Nov;30(9):1943-9. doi: 10.1016/j.ajem.2012.04.015. Epub 2012 Jul 12.

Abstract

PURPOSES

Emergency physician-performed ultrasonography holds promise as a rapid and accurate method to diagnose multiple diseases in the emergency department (ED). Our objective was to assess the initial diagnostic accuracy (first 55 explorations) of emergency physician-performed ultrasonography for multiple categories of ultrasound use after a short training period.

BASIC PROCEDURES

This was a prospective observational study conducted at an urban ED from June 2010 to March 2011 in patients with suspected cholecystitis, hydronephrosis, deep vein thrombosis, and different cardiovascular problems. Five physicians had a 10-hour training session before enrolling patients. The test characteristics of bedside ultrasonography were determined with the final radiologist/cardiologist interpretation.

MAIN FINDINGS

A total of 275 ultrasonographic examinations were performed (78 abdominal explorations, 80 renal explorations, 76 2-point compression ultrasonographic examinations in patients with suspected deep vein thrombosis, and 41 echocardiograms in patients with different acute cardiovascular problems). Radiologists/cardiologists detected 28 cases of cholecystitis, 26 cases of deep vein thrombosis, 49 cases of hydronephrosis, and 15 cases of significant cardiovascular alterations. The overall diagnostic accuracy of ED ultrasonograms yielded a sensitivity, specificity, positive predictive value, and negative predictive value of 92.6% (95% confidence interval [CI], 90%-99%), 89% (95% CI, 84%-94%), 86.2 % (95% CI, 82%-93%), and 94.2% (95% CI, 92%-99%), respectively. Nineteen (6.9%) false-positive results and 6 false-negative results (2.1%) were obtained.

PRINCIPAL CONCLUSIONS

Emergency physicians in our institution attained reasonably high initial accuracy in the performance of ultrasonography for a variety of clinical problems after a 10-hour training period.

摘要

目的

急诊医师实施的超声检查有望成为一种快速准确的方法,可用于在急诊科(ED)诊断多种疾病。我们的目的是评估经过短期培训后,急诊医师在多种超声使用类别中的初始诊断准确性(前 55 次检查)。

基本程序

这是一项前瞻性观察性研究,于 2010 年 6 月至 2011 年 3 月在疑似胆囊炎、肾积水、深静脉血栓形成和不同心血管问题的患者中在城市急诊科进行。5 名医生在入组患者之前进行了 10 小时的培训课程。床旁超声检查的测试特征是通过最终的放射科医生/心脏病专家的解释来确定的。

主要发现

共进行了 275 次超声检查(78 次腹部探查、80 次肾脏探查、76 次疑似深静脉血栓形成的 2 点压迫超声检查、41 次不同急性心血管问题的超声心动图)。放射科医生/心脏病专家发现 28 例胆囊炎、26 例深静脉血栓形成、49 例肾积水和 15 例明显心血管改变。ED 超声检查的总体诊断准确性为 92.6%(95%置信区间[CI],90%-99%)、89%(95%CI,84%-94%)、86.2%(95%CI,82%-93%)和 94.2%(95%CI,92%-99%)的敏感性、特异性、阳性预测值和阴性预测值。分别获得 19 次(6.9%)假阳性结果和 6 次(2.1%)假阴性结果。

主要结论

在经过 10 小时的培训后,我们机构的急诊医生在执行多种临床问题的超声检查时,最初的准确性相当高。