Kawata Manabu, Hasegawa Takashi
Laboratory of Advanced Diagnosis and Treatment, Department of Advanced Clinical Medicine, Course of Veterinary Sciences, Graduate School of Life and Environmental Sciences, Osaka Prefecture University, North 1-58, Rinku-orai, Izumisano 598-8531, Japan.
Vet Ophthalmol. 2013 May;16(3):169-74. doi: 10.1111/j.1463-5224.2012.01043.x. Epub 2012 Jul 18.
To determine whether the distance between Schwalbe's line (the peripheral termination of Descemet's membrane, i.e., the borderline between the cornea and sclera) and the anterior lens capsule (SLD) is an applicable parameter for correcting raw ultrasound biomicroscopic values of the canine iridocorneal angle (ICA) and to establish a comparative system for the ICA values in different canine breeds with varied body sizes/weights.
The dogs were divided into four groups based on body weight (BW): <4 kg, 4-8 kg, 8-20 kg, and >20 kg, and 180 normotensive eyes were studied.
The ICA microstructure was examined by ultrasound biomicroscopy (UBM) using 40-MHz probes in dogs with or without anesthesia/sedation. Linear regression analysis and correlation coefficients were evaluated between SLD or SLD(2) and UBM measurements; subsequently, noncorrected and SLD-corrected UBM values were statistically assessed.
Significant linear correlations were detected between SLD and the ciliary cleft width, the minimum distance between the angle recess and the scleral venous plexus, and the scleral thickness. Positive linear correlations were also demonstrated between SLD(2) and the ciliary cleft area as well as the scleral venous plexus area. Raw UBM measurements were corrected by using a ratio with SLD on the distance or SLD(2) on the area. Although noncorrected UBM measurements increased with canine BW, SLD-corrected UBM values remained similar with no significant statistical differences in any of the dogs.
Correction with SLD would be clinically useful for comparing UBM measurements of the ICA in dogs with different body sizes/weights.
确定施瓦贝线(后弹力层的周边终止处,即角膜与巩膜的边界)与晶状体前囊膜之间的距离(SLD)是否为校正犬虹膜角膜角(ICA)原始超声生物显微镜测量值的适用参数,并建立不同体型/体重犬种ICA值的比较系统。
根据体重(BW)将犬分为四组:<4 kg、4 - 8 kg、8 - 20 kg和>20 kg,共研究180只血压正常的眼睛。
使用40兆赫探头,通过超声生物显微镜(UBM)在麻醉或未麻醉/镇静的犬中检查ICA微观结构。评估SLD或SLD(2)与UBM测量值之间的线性回归分析和相关系数;随后,对未校正和SLD校正的UBM值进行统计学评估。
在SLD与睫状沟宽度、房角隐窝与巩膜静脉丛之间的最小距离以及巩膜厚度之间检测到显著的线性相关性。在SLD(2)与睫状沟面积以及巩膜静脉丛面积之间也显示出正线性相关性。通过使用距离上的SLD或面积上的SLD(2)的比率来校正原始UBM测量值。尽管未校正的UBM测量值随犬体重增加,但SLD校正后的UBM值在所有犬中均保持相似,无显著统计学差异。
用SLD进行校正对于比较不同体型/体重犬的ICA的UBM测量值在临床上是有用的。