Suppr超能文献

不同 b 值下弥散加权成像中乳腺病变的显著性。

Conspicuity of breast lesions at different b values on diffusion-weighted imaging.

机构信息

Department of Radiology, Second Affiliated Hospital of Medical College of Xi'an Jiaotong University, Xiwu Road, Xi'an, Shannxi, China.

出版信息

BMC Cancer. 2012 Aug 2;12:334. doi: 10.1186/1471-2407-12-334.

Abstract

BACKGROUND

Diffusion-weighted (DW) imaging has shown potential to differentiate between malignant and benign breast lesions. However, different b values have been used with varied sensitivity and specificity. This study aims to prospectively evaluate the influence of b value on the detection and assessment of breast lesions.

METHODS

Institutional review board approval and informed patient consent were obtained. Between February 2010 and September 2010, sixty women suspected of having breast cancer by clinical examination and mammography underwent bilateral breast MRI and DW imaging (with maximum b values of 600, 800, and 1000 s/mm(2)). Conspicuity grades of lesions at different b values on DW images were performed. Signal intensity and apparent diffusion coefficient (ADC) values were recorded and compared among different b values by the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and receiver operating characteristic (ROC) curve.

RESULTS

Fifty-seven lesions from 52 recruited patients including 39/57 (68%) malignant and 18/57 (32%) benign were confirmed with pathology. DCE MRI accurately detected 53 lesions with the sensitivity of 93.0% and specificity of 66.7%, and DW imaging accurately detected 51 lesions with the sensitivity of 89.5% and specificity of 100%. There were no significant differences in conspicuity grades compared among the three b values (P = 0.072), although the SNR and CNR of breast lesions decreased significantly with higher b values. Mean ADCs of malignant lesions (b = 600 s/mm(2), 1.07 ± 0.26 × 10-3 mm(2)/s; b = 800 s/mm(2), 0.96 ± 0.22 × 10-3 mm(2)/s; b = 1000 s/mm(2), 0.92 ± 0.26 × 10-3 mm(2)/s) were significantly lower than those of benign lesions (b = 600 s/mm(2), 1.55 ± 0.40 × 10-3 mm(2)/s; b = 800 s/mm(2), 1.43 ± 0.38 × 10-3 mm(2)/s; b = 1000 s/mm(2), 1.49 ± 0.38 × 10-3 mm(2)/s) with all P values <0.001, but there were no significant differences among the three b values (P = 0.303 and 0.840 for malignant and benign lesions, respectively). According to the area under the ROC curves, which were derived from ADC and differentiate malignant from benign lesions, no significant differences were found among the three b values (P = 0.743).

CONCLUSIONS

DW imaging is a potential adjunct to conventional MRI in the differentiation between malignant and benign breast lesions. Varying the maximum b value from 600 to 1000 s/mm(2) does not influence the conspicuity of breast lesions on DW imaging at 1.5 T.

摘要

背景

扩散加权(DW)成像已显示出区分良恶性乳腺病变的潜力。然而,不同的 b 值具有不同的敏感性和特异性。本研究旨在前瞻性评估 b 值对乳腺病变检测和评估的影响。

方法

获得机构审查委员会批准和患者知情同意。2010 年 2 月至 2010 年 9 月,60 名经临床检查和乳房 X 线摄影怀疑患有乳腺癌的女性接受了双侧乳腺 MRI 和 DW 成像(最大 b 值为 600、800 和 1000 s/mm²)。对 DW 图像上不同 b 值的病变进行了显影程度分级。记录了信号强度和表观扩散系数(ADC)值,并通过信噪比(SNR)、对比噪声比(CNR)和受试者工作特征(ROC)曲线比较不同 b 值之间的 ADC 值。

结果

52 名入组患者的 57 个病灶中,39/57(68%)为恶性,18/57(32%)为良性,均经病理证实。DCE MRI 准确检出 53 个病灶,敏感性为 93.0%,特异性为 66.7%,DW 成像准确检出 51 个病灶,敏感性为 89.5%,特异性为 100%。虽然随着 b 值的升高,乳腺病变的 SNR 和 CNR 显著降低,但三种 b 值之间的显影程度分级无显著差异(P=0.072)。恶性病变的平均 ADC 值(b=600 s/mm²,1.07±0.26×10-3 mm²/s;b=800 s/mm²,0.96±0.22×10-3 mm²/s;b=1000 s/mm²,0.92±0.26×10-3 mm²/s)明显低于良性病变(b=600 s/mm²,1.55±0.40×10-3 mm²/s;b=800 s/mm²,1.43±0.38×10-3 mm²/s;b=1000 s/mm²,1.49±0.38×10-3 mm²/s),所有 P 值均<0.001,但三种 b 值之间无显著差异(恶性和良性病变的 P 值分别为 0.303 和 0.840)。根据 ROC 曲线下面积,ADC 可区分良恶性病变,三种 b 值之间无显著差异(P=0.743)。

结论

DW 成像在良恶性乳腺病变的鉴别中是常规 MRI 的一种潜在补充。在 1.5T 下,改变最大 b 值从 600 到 1000 s/mm²不会影响 DW 成像上乳腺病变的显影程度。