Suppr超能文献

帕金森病患者无仪器步行测试的可靠性。

Reliability of the non-instrumented walk test in persons with Parkinson's disease.

机构信息

Michael E DeBakey Veterans Affairs Medical Center, Houston, TX 77030, USA.

出版信息

Disabil Rehabil. 2013 Apr;35(7):538-42. doi: 10.3109/09638288.2012.709910. Epub 2012 Aug 14.

Abstract

PURPOSE

To study the reliability of a Non-Instrumented Walk Test in individuals with Parkinson's disease (PD).

METHOD

Thirty individuals (21 Males) with PD were studied. Their mean age was 68.90 ± 9.28 years. The average time since diagnosis was 8.75 ± 5.68 years. The reliability of the manual Non-Instrumented Walk Test was studied while "OFF" and "ON" dopaminergic medication. Subjects walked at their self-selected, usual speed during a Non-Instrumented Walk Test and while walking on a computerized instrumented walkway. Intraclass correlation coefficients (ICCs) were calculated and means were compared for three gait parameters as measured by the two methods.

RESULTS

During "OFF" medication testing, ICCs between the Non-Instrumented Walk Test and the instrumented measures for gait speed, cadence and stride length were 0.96 (p < 0.0005), 0.72 (p = 0.001) and 0.97 (p < 0.0005), respectively. During "ON" medication testing, the ICCs were 0.96 (p < 0.0005), 0.86 (p < 0.0005) and 0.96 (p < 0.0005), respectively. The means of the non-instrumented measures tended to be lower than those obtained on the instrumented walkway.

CONCLUSIONS

The Non-Instrumented Walk Test is a quick, simple and inexpensive gait evaluation for individuals with PD. The method is sufficiently reliable to be used clinically in this population during different medication cycles.

IMPLICATIONS FOR REHABILITATION

• The Non-Instrumented Walk Test in individuals with PD is reliable. • Results supported the use of the measure. This simple walk test is quick and easy to administer in both clinical and community settings.

摘要

目的

研究非仪器步行测试在帕金森病(PD)患者中的可靠性。

方法

研究了 30 名(21 名男性)PD 患者。他们的平均年龄为 68.90 ± 9.28 岁。平均诊断时间为 8.75 ± 5.68 年。在“关闭”和“开启”多巴胺能药物时,研究了手动非仪器步行测试的可靠性。受试者在非仪器步行测试和计算机化仪器步行道上以自我选择的通常速度行走。使用两种方法测量三个步态参数时,计算了组内相关系数(ICC)并比较了平均值。

结果

在“关闭”药物测试期间,非仪器步行测试与仪器测量的步态速度、步频和步长的 ICC 分别为 0.96(p < 0.0005)、0.72(p = 0.001)和 0.97(p < 0.0005)。在“开启”药物测试期间,ICC 分别为 0.96(p < 0.0005)、0.86(p < 0.0005)和 0.96(p < 0.0005)。非仪器测量的平均值往往低于仪器步行道上获得的值。

结论

非仪器步行测试是一种快速、简单且经济的 PD 患者步态评估方法。该方法在不同药物周期内对该人群进行临床应用具有足够的可靠性。

对康复的影响

  • PD 患者的非仪器步行测试是可靠的。

  • 结果支持该措施的使用。这种简单的步行测试在临床和社区环境中都易于快速且轻松地进行管理。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3b9e/4167404/d62730b2fe85/nihms626278f1.jpg

相似文献

1
Reliability of the non-instrumented walk test in persons with Parkinson's disease.帕金森病患者无仪器步行测试的可靠性。
Disabil Rehabil. 2013 Apr;35(7):538-42. doi: 10.3109/09638288.2012.709910. Epub 2012 Aug 14.

本文引用的文献

9
Optimal walking in terms of variability in step length.就步长变异性而言的最佳行走方式。
J Orthop Sports Phys Ther. 1997 Nov;26(5):266-72. doi: 10.2519/jospt.1997.26.5.266.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验