Suppr超能文献

老视性准分子激光原位角膜磨镶术后的视觉质量评估

Visual quality assessment after presbyopic laser keratomileusis.

作者信息

Lim Dong Hui, Chung Eui-Sang, Kim Myoung Joon, Chung Tae-Young

机构信息

Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.

Department of Preventive Medicine, Graduate School, the Catholic University of Korea, Seoul 06591, Korea.

出版信息

Int J Ophthalmol. 2018 Mar 18;11(3):462-469. doi: 10.18240/ijo.2018.03.17. eCollection 2018.

Abstract

AIM

To assess visual quality after presbyopia correction using an aspheric ablation profile and a micro-monovision protocol.

METHODS

This is a retrospective interventional study. Fifty-four eyes of 27 patients (mean age, 50.2±7.5y) who underwent presbyopia correction with an aspheric micro-monovision protocol were enrolled. The values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI) and accommodation range were quantitatively assessed using the HD analyzer. Preoperative and postoperative contrast sensitivity (CS) at far (2.5 m) and near (40 cm) distance and higher-order aberrations (HOAs) were analyzed. Subjective visual satisfaction was evaluated by self-reported questionnaire regarding optical visual symptoms.

RESULTS

One year after presbyopia correction, no significant differences were found in the MTF cutoff frequency, Strehl ratio and OSI, however, the HD analyzer accommodation range significantly differed postoperatively (=0.004). Postoperative CS at 12 and 18 cpd at near showed statistically significant improvement (=0.020 and 0.008, respectively). Visual performance by self-reported questionnaire revealed satisfactory results in terms of subjective visual quality improvement.

CONCLUSION

Objective optical quality parameters show good visual outcomes. Subjective visual quality assessed by self-reported questionnaire in the presbyopia correction group show satisfactory results.

摘要

目的

使用非球面消融模式和微单眼视方案评估老视矫正后的视觉质量。

方法

这是一项回顾性干预研究。纳入27例患者(平均年龄50.2±7.5岁)的54只眼,这些患者接受了非球面微单眼视方案的老视矫正。使用高清分析仪定量评估调制传递函数(MTF)截止频率、斯特列尔比率、客观散射指数(OSI)和调节范围的值。分析术前和术后在远距(2.5米)和近距(40厘米)的对比敏感度(CS)以及高阶像差(HOA)。通过关于视觉光学症状的自我报告问卷评估主观视觉满意度。

结果

老视矫正一年后,MTF截止频率、斯特列尔比率和OSI无显著差异,然而,高清分析仪的调节范围术后有显著差异(P = 0.004)。术后近距12和18周/度的CS有统计学显著改善(分别为P = 0.020和0.008)。自我报告问卷的视觉表现显示主观视觉质量改善方面结果令人满意。

结论

客观光学质量参数显示出良好的视觉效果。老视矫正组通过自我报告问卷评估的主观视觉质量显示结果令人满意。

相似文献

1
Visual quality assessment after presbyopic laser keratomileusis.老视性准分子激光原位角膜磨镶术后的视觉质量评估
Int J Ophthalmol. 2018 Mar 18;11(3):462-469. doi: 10.18240/ijo.2018.03.17. eCollection 2018.

引用本文的文献

本文引用的文献

1
PresbyLASIK approach for the correction of presbyopia.用于矫正老花眼的准分子原位角膜磨镶术方法。
Curr Opin Ophthalmol. 2015 Jul;26(4):265-72. doi: 10.1097/ICU.0000000000000162.
2
A review of the surgical options for the correction of presbyopia.老视矫正手术选择的综述。
Br J Ophthalmol. 2016 Jan;100(1):62-70. doi: 10.1136/bjophthalmol-2015-306663. Epub 2015 Apr 23.
3

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。