Lee Tsui-Tsui, Cho Pauline
School of Optometry, The Hong Polytechnic University, Hung Hom, Hong Kong, China.
Optom Vis Sci. 2012 Oct;89(10):1477-86. doi: 10.1097/OPX.0b013e31826912cd.
To determine the repeatability of relative peripheral refraction (RPR) measurements using an open-view automatic refractor in untreated and orthokeratology (ortho-k)-treated eyes of children.
Cycloplegic central (CR) and peripheral refraction (PR) across the central 60° horizontal field at 10° intervals were measured in children (6-9 years) using a Shin-Nippon NVision K5001 autorefractor. In experiment 1, measurements were repeated at the same visit for 59 untreated (right) eyes, whereas in experiment 2, measurements were repeated at the same visit and another visit (1-2 weeks apart) for 24 ortho-k-treated (right) eyes to determine the intra- and intervisit repeatability, respectively. Measurements were transposed into M, J0, and J45 vectors, and RPR were calculated by subtracting central refraction from PR values. Intra- and intervisit differences and coefficients of repeatability (COR) of RPR were determined.
The mean intravisit differences in RPR for all three vectors were ≤0.05 D for untreated eyes, and both intra- and intervisit differences in RPR were ≤0.32 D for ortho-k-treated eyes. No significant intra- and intervisit differences in RPR were found at any field angle in this study. COR of measurements were <±0.71 D in the untreated eyes, and <±1.25 D (intravisit) and <±3.00 D (intervisit) in ortho-k-treated eyes. The COR increased with field angles in all situations and were greater in ortho-k-treated than in untreated eyes. In ortho-k-treated eyes, intervisit COR of measurements beyond central 40° field were larger than the intravisit COR.
The mean intra- and intervisit differences of RPR measurements were small in both untreated and ortho-k-treated eyes. Variability of PR measurements increased with field angle and with ortho-k treatment.
使用开放式自动验光仪确定儿童未经治疗和接受角膜塑形术(ortho-k)治疗的眼睛中相对周边屈光(RPR)测量的可重复性。
使用日本新日本株式会社NVision K5001自动验光仪对6至9岁儿童的中央60°水平视野内以10°间隔的睫状肌麻痹下中央(CR)和周边屈光(PR)进行测量。在实验1中,对59只未经治疗的(右眼)眼睛在同一次就诊时重复测量,而在实验2中,对24只接受ortho-k治疗的(右眼)眼睛在同一次就诊以及另一次就诊(间隔1至2周)时重复测量,分别以确定就诊内和就诊间的可重复性。测量值转换为M、J0和J45向量,并通过从PR值中减去中央屈光来计算RPR。确定RPR的就诊内和就诊间差异以及可重复性系数(COR)。
未经治疗的眼睛中,所有三个向量的RPR平均就诊内差异≤0.05 D,接受ortho-k治疗的眼睛中,RPR的就诊内和就诊间差异均≤0.32 D。在本研究中,在任何视野角度均未发现RPR有显著的就诊内和就诊间差异。未经治疗的眼睛中测量的COR <±0.71 D,接受ortho-k治疗的眼睛中,就诊内COR <±1.25 D,就诊间COR <±3.00 D。在所有情况下,COR均随视野角度增加,且接受ortho-k治疗的眼睛中的COR大于未经治疗的眼睛。在接受ortho-k治疗的眼睛中,中央40°视野以外测量的就诊间COR大于就诊内COR。
未经治疗和接受ortho-k治疗的眼睛中,RPR测量的平均就诊内和就诊间差异均较小。PR测量的变异性随视野角度和ortho-k治疗而增加。