Fruit and vegetable (F/V) intake assessment tools that are valid, reliable, brief, and easy to administer and code are vital to the field of public health nutrition.
To evaluate three short F/V intake screeners (ie, a 2-item serving tool, a 2-item cup tool, and a 16-item F/V intake screener) among adults using multiple 24-hour dietary recalls (24-hour recalls) as the reference instrument and evaluate test-retest reliability of the screeners across a 2- to 3-week time period.
Validity and reliability study.
PARTICIPANTS/SETTING: Two hundred forty-four adults for the validity study and 335 adults for test-retest reliability.
Median values for F/V intakes were calculated for the screeners and 24-hour recalls. The Wilcoxon signed rank test was used to compare screeners with the 24-hour recalls. Deattenuated Pearson correlations were reported for validity and intraclass correlation coefficient used for reliability.
The estimated median daily servings/cups of F/V for the 2-item serving screener was lower, for the 2-item cup screener was equivalent for men but higher for women, and for the 16-item F/V intake screener were about the same when compared with 24-hour recall values. The deattenuated correlations comparing the 24-hour recalls with the screeners were positive but weak for the 2-item serving screener, and were positive and moderate in strength for the 2-item cup and 16-item F/V intake screeners. The test-retest intraclass correlation coefficients were all positive and fairly strong for all of the screeners.
Although dietary screeners offer a more cost-effective, less burdensome way to obtain gross estimates to rank individuals with regard to F/V intake, these methods are not recommended for assessing precise intake levels.
对于公共卫生营养领域来说,有效的、可靠的、简洁的、易于管理和编码的水果和蔬菜(F/V)摄入量评估工具是至关重要的。
使用多次 24 小时膳食回忆(24 小时回忆)作为参考仪器,评估三种简短的 F/V 摄入量筛查工具(即 2 项份量工具、2 项杯具工具和 16 项 F/V 摄入量筛查器)在成年人中的有效性,并评估筛查器在 2 至 3 周时间内的重测信度。
有效性和可靠性研究。
参与者/设置:有效性研究纳入 244 名成年人,重测信度研究纳入 335 名成年人。
为筛查器和 24 小时回忆计算 F/V 摄入量的中位数。使用 Wilcoxon 符号秩检验比较筛查器与 24 小时回忆。报告有效性的去衰减 Pearson 相关系数和可靠性的组内相关系数。
与 24 小时回忆值相比,2 项份量筛查器估计的每日平均 F/V 份/杯数较低,2 项杯具筛查器对男性而言相当,但对女性而言较高,而 16 项 F/V 摄入量筛查器则大致相同。与 24 小时回忆相比,2 项份量筛查器的去衰减相关性为正但较弱,2 项杯具和 16 项 F/V 摄入量筛查器的相关性为正且强度适中。所有筛查器的重测组内相关系数均为正且相当强。
虽然饮食筛查器提供了一种更具成本效益、负担更小的方法来获得总体估计值,以便对 F/V 摄入量进行个体排名,但这些方法不建议用于评估精确的摄入量水平。