Baysal Asli, Uysal Tancan, Gul Nisa, Alan Melike Busra, Ramoglu Sabri Ilhan
Department of Orthodontics, Faculty of Dentistry, Izmir Katip Celebi University, Izmir, Turkey.
Korean J Orthod. 2012 Feb;42(1):39-46. doi: 10.4041/kjod.2012.42.1.39. Epub 2012 Feb 27.
We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication.
We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire.
Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001).
Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers.
我们评估了用于制作粘结式舌侧保持器的3种不同钢丝的分离力、变形量、断裂模式和拔出力。
我们测试了0.0215英寸的五股钢丝(PentaOne,Masel;第一组)、0.016×0.022英寸的特软八编织钢丝(Bond-A-Braid,Reliance;第二组)和0.0195英寸的特软同轴钢丝(Respond,Ormco;第三组)。为了测试分离力、变形和断裂模式,我们将94颗下切牙成对嵌入丙烯酸树脂块中。将保持器钢丝粘结到牙齿上,并对钢丝施加垂直方向的力。为了测试拔出力,将钢丝嵌入放置在丙烯酸树脂块中心孔中的复合材料中。沿着钢丝的长轴施加拉力。
各组之间的分离力和断裂模式没有差异。第二组和第三组的变形明显高于第一组(p<0.001)。与第二组和第三组相比,第一组的平均拔出力明显更高(p<0.001)。
所有钢丝的分离力和断裂模式相似,但特软钢丝的变形更大。五股同轴钢丝的拔出力明显高于其他测试钢丝。建议在粘结式舌侧保持器中使用五股同轴钢丝。