In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

摘要

为了检测减肥类保健品中是否非法添加利尿剂,我们开发了一种使用 HPLC 和 LC-MS/MS 同时分析保健品中 17 种利尿剂的简单、快速、选择性和灵敏的方法。HPLC 条件采用 Capcell-pak C18,流动相采用梯度条件,UV 检测波长为 254nm,并对其进行了线性(r(2)>0.999)、精密度(CV≤3%)、回收率(90.4-102.8%)和重现性验证。通过离子喷雾 LC-MS/MS 采用多重反应监测(MRM)进行 17 种利尿剂的鉴定和定量。反相机制下在 HSS-T3 柱上进行色谱分离。LC-MS/MS 方法的线性(r(2)>0.99)和精密度(CV<13%)均得到验证。用所建立的方法对 16 种保健品进行了检测,所有样品中均未检出利尿剂。还考察了提取回收率,HPLC 和 LC-MS/MS 法在不同配方中的提取回收率分别为 88%-110%和 81%-116%。不同类型保健品的回收率无显著差异。基于这一结果,使用 HPLC 和 LC-MS/MS 监测保健品中非法药物掺假的方法简单、快速、可靠。因此,适用于常规药物掺假筛查。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验