评价涂层型洗必泰缓释漆的导尿管在减轻犬导尿管生物膜形成中的作用。

Evaluation of urinary catheters coated with sustained-release varnish of chlorhexidine in mitigating biofilm formation on urinary catheters in dogs.

机构信息

Koret School of Veterinary Medicine, the Hebrew University of Jerusalem, Israel.

出版信息

J Vet Intern Med. 2013 Jan-Feb;27(1):39-46. doi: 10.1111/j.1939-1676.2012.01027.x. Epub 2012 Nov 9.

Abstract

BACKGROUND

Biofilm formation occurs commonly on urinary catheters.

OBJECTIVES

To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs.

ANIMALS

Thirty client-owned dogs.

METHODS

Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy.

RESULTS

None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04).

CONCLUSIONS AND CLINICAL IMPORTANCE

Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs.

摘要

背景

生物膜形成通常发生在导尿管上。

目的

评估涂有氯己定缓释清漆的导尿管在减少犬导尿管相关生物膜形成方面的效果。

动物

30 只患犬。

方法

前瞻性研究。13 只犬使用涂有氯己定缓释清漆的导尿管进行导尿(研究组),13 只犬使用未处理的导尿管进行导尿(对照组)。通过评估生物膜细菌的菌落形成单位(CFU),并用共聚焦激光扫描显微镜和电子显微镜半定量地评估两组导尿管上生物膜形成的存在和强度。

结果

没有犬出现与导尿管存在相关的不良反应。与对照组相比,研究组所有部位导尿管上生物膜细菌的 CFU 计数均显著降低(P<.001)。与对照组相比,研究组导尿管上生物膜形成的程度通过共聚焦激光扫描显微镜和电子显微镜评估明显更低。电子显微镜检查发现一些导尿管上有晶体。在研究组中,与对照组相比,晶体观察到的导尿管比例在导尿管的远端明显较低(分别为 16.7%和 66.7%;P=0.04)。

结论和临床意义

氯己定缓释清漆涂层导尿管可有效减少犬导尿管相关生物膜的形成。