Suppr超能文献

传统植入或使用压电手术®安装的具有树枝状聚合物表面特征的种植体的骨结合。在犬类中的一项比较研究。

Osseointegration of implants with dendrimers surface characteristics installed conventionally or with Piezosurgery®. A comparative study in the dog.

作者信息

Bengazi Franco, Lang Niklaus P, Canciani Elena, Viganò Paolo, Velez Joaquin Urbizo, Botticelli Daniele

机构信息

Faculty of Dentistry, University of Medical Science, La Habana, Cuba.

出版信息

Clin Oral Implants Res. 2014 Jan;25(1):10-5. doi: 10.1111/clr.12082. Epub 2012 Dec 12.

Abstract

AIM

The first aim of the present experiment was to compare bone healing at implants installed in recipient sites prepared with conventional drills or a piezoelectric device. The second aim was to compare implant osseointegration onto surfaces with and without dendrimers coatings.

MATERIAL AND METHODS

Six Beagles dogs were used in this study. Five implants with two different surfaces, three with a ZirTi(®) surface (zirconia sand blasted, acid etched), and two with a ZirTi(®)-modified surface with dendrimers of phosphoserine and polylysine were installed in the right side of the mandible. In the most anterior region (P2, P3), two recipient sites were prepared with drills, and one implant ZirTi(®) surface and one coated with dendrimers implants were installed at random. In the posterior region (P4 and M1), three recipient sites were randomly prepared: two sites with a Piezosurgery(®) instrument and one site with drill and two ZirTi(®) surface and one coated with dendrimers implants installed. Three months after the surgery, the animals were sacrificed for histological analysis.

RESULTS

No complications occurred during the healing period. Three implants were found not integrated and were excluded from analysis. However, n = 6 was obtained. The distance IS-B at the buccal aspect was 2.2 ± 0.8 and 1.8 ± 0.5 mm, while IS-C was 1.5 ± 0.9 and 1.4 ± 0.6 mm at the Piezosurgery(®) and drill groups, respectively. Similar values were obtained between the dendrimers-coated and ZirTi(®) surface implants. The BIC% values were higher at the drill (72%) compared to the Piezosurgery(®) (67%) sites. The BIC% were also found to be higher at the ZirTi(®) (74%) compared to the dendrimers-coated (65%) implants, the difference being statistically significant.

CONCLUSION

This study has revealed that oral implants may osseointegrate equally well irrespective of whether their bed was prepared utilizing conventional drills with abundant cooling or Piezosurgery(®). Moreover, the surface coating of implants with dendrimers phosphoserine and polylysine did not improve osseointegration.

摘要

目的

本实验的首要目的是比较在使用传统钻头或压电装置制备的受体部位植入的种植体的骨愈合情况。第二个目的是比较种植体在有和没有树枝状聚合物涂层的表面上的骨结合情况。

材料与方法

本研究使用了6只比格犬。在下颌右侧植入5枚具有两种不同表面的种植体,其中3枚为ZirTi(®)表面(氧化锆喷砂、酸蚀),2枚为带有磷酸丝氨酸和聚赖氨酸树枝状聚合物的ZirTi(®)改性表面。在最前部区域(P2、P3),用钻头制备两个受体部位,随机植入一枚ZirTi(®)表面种植体和一枚涂有树枝状聚合物的种植体。在后部区域(P4和M1),随机制备三个受体部位:两个部位使用Piezosurgery(®)器械,一个部位使用钻头,并植入两枚ZirTi(®)表面种植体和一枚涂有树枝状聚合物的种植体。术后三个月,处死动物进行组织学分析。

结果

愈合期未出现并发症。发现3枚种植体未结合,被排除在分析之外。然而,最终获得n = 6的数据。颊侧的IS-B距离在Piezosurgery(®)组和钻头组分别为2.2±0.8和1.8±0.5毫米,而IS-C距离分别为1.5±0.9和1.4±0.6毫米。涂有树枝状聚合物的种植体和ZirTi(®)表面种植体之间获得了相似的值。与Piezosurgery(®)部位(67%)相比,钻头部位的骨结合率(BIC%)值更高(72%)。还发现与涂有树枝状聚合物的种植体(65%)相比,ZirTi(®)种植体的BIC%更高(74%),差异具有统计学意义。

结论

本研究表明,无论种植体植入床是使用大量冷却的传统钻头还是Piezosurgery(®)制备,口腔种植体的骨结合情况可能同样良好。此外,用磷酸丝氨酸和聚赖氨酸树枝状聚合物对种植体表面进行涂层并不能改善骨结合情况。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验