Ahmad Shafeeque, Kalra Harsh, Gupta Amit, Raut Bharat, Hussain Arshad, Rahman Md Akhlaquer
School of Pharmacy and Technology Management, NMIMS University, Mumbai, India.
J Pharm Bioallied Sci. 2012 Oct;4(4):267-75. doi: 10.4103/0975-7406.103234.
When complex biological materials are analyzed without an adequate sample preparation technique, MS signal and response undergo significant alteration and result in poor quantification and assay. This problem generally takes place due to the presence of several endogenous materials component in samples. One of the major causes of ion suppression in bioanalysis is the presence of phospholipids during LC-MS analysis. The phospholipid-based matrix effect was investigated with a commercially available electro spray ionization (ESI) source coupled with a triple quadrupole mass spectrometer. HybridSPE dramatically reduced the levels of residual phospholipids in biological samples, leading to significant reduction in matrix effects. This new procedure that combines the simplicity of precipitation with the selectivity of SPE allows obtaining much cleaner extracts than with conventional procedures. HybridSPE-precipitation procedure provides significant improvement in bioanalysis and a practical and fast way to ensure the avoidance of phospholipids-based matrix effects. The present review outlines the HybridSPE technique to minimize phospholipids-based matrix effects on LC-ESI-MS bioanalysis.
在没有适当的样品制备技术的情况下分析复杂生物材料时,质谱信号和响应会发生显著变化,导致定量和测定效果不佳。这个问题通常是由于样品中存在多种内源性物质成分而发生的。生物分析中离子抑制的主要原因之一是液相色谱 - 质谱分析过程中磷脂的存在。使用市售的电喷雾电离(ESI)源与三重四极杆质谱仪相结合,研究了基于磷脂的基质效应。混合固相萃取(HybridSPE)显著降低了生物样品中残留磷脂的水平,从而显著降低了基质效应。这种将沉淀的简便性与固相萃取的选择性相结合的新方法,能够获得比传统方法更纯净的提取物。HybridSPE沉淀法在生物分析方面有显著改进,是一种实用且快速的方法,可确保避免基于磷脂的基质效应。本综述概述了HybridSPE技术,以尽量减少基于磷脂的基质效应在液相色谱 - 电喷雾电离 - 质谱生物分析中的影响。