Suppr超能文献

采用串联质量标签和 LTQ Orbitrap XL 电子转移解离混合质谱仪直接分析糖蛋白的定性和定量特征。

Direct approach for qualitative and quantitative characterization of glycoproteins using tandem mass tags and an LTQ Orbitrap XL electron transfer dissociation hybrid mass spectrometer.

机构信息

U.S. Food and Drug Administration, CDER, DPA, St. Louis, Missouri 63101, United States.

出版信息

Anal Chem. 2013 Feb 5;85(3):1531-9. doi: 10.1021/ac3026465. Epub 2013 Jan 14.

Abstract

The application of multiplexed isobaric tandem mass tag (TMT) labeling and an LTQ Orbitrap XL ETD (electron transfer dissociation) hybrid mass spectrometer as a direct approach for qualitative and quantitative characterization of glycoproteins is reported. Bovine fetuin was used as a model glycoprotein in this study. For online liquid chromatography-mass spectrometry (LC-MS) analysis, high-resolution, mass accurate full scan MS spectra were acquired in the Orbitrap mass analyzer followed by data-dependent tandem mass spectrometry (MS/MS) with alternating collision-induced dissociation (CID), ETD, and higher-energy collisional dissociation (HCD) scans. An additional in-source dissociation scan was used as a highly sensitive and selective detection method for eluting glycosylated peptides. By alternatively using three different dissociation methods, 23 glycoforms from all 5 corresponding glycopeptides were identified from a trypsin digest of bovine fetuin. With ETD, labile glycans were retained without any signs of carbohydrate cleavage with concurrent fragmentation of the peptide backbone. Glycosylation sites were clearly localized from the ETD fragmentation data. Glycan structure elucidation was accomplished using CID. The CID experiments generated fragment ions predominantly from cleavage of glycosidic bonds without breaking the peptide bond. Novel to this method, the TMT labeling protocol was modified and adapted for higher labeling efficiency, and a TriVersa NanoMate was used to reinfuse samples to improve ETD and HCD spectra of glycopeptides. Quantification with TMT was verified based on the HCD spectra from multiple nonglycopeptides and glycopeptides. This method can be used as a qualitative and quantitative technique for direct characterization of glycoproteins and has applicability for detection of counterfeit glycoprotein drug products.

摘要

本文报道了一种将多重同位素质谱标签(TMT)标记与 LTQ Orbitrap XL ETD(电子转移解离)混合质谱仪联用,直接用于糖蛋白定性和定量分析的方法。牛胎球蛋白被用作本研究的模型糖蛋白。对于在线液相色谱-质谱(LC-MS)分析,在 Orbitrap 质量分析仪中获得高分辨率、质量精确的全扫描 MS 谱,然后进行数据依赖的串联质谱(MS/MS)分析,交替使用碰撞诱导解离(CID)、ETD 和更高能量碰撞解离(HCD)扫描。另外,源内解离扫描可作为一种高灵敏度和选择性的检测方法,用于洗脱糖基化肽。通过交替使用三种不同的解离方法,从牛胎球蛋白的胰蛋白酶消化物中鉴定出了 5 个相应糖肽的所有 23 种糖型。使用 ETD,不稳定的聚糖在没有任何碳水化合物裂解迹象的情况下保留下来,同时肽骨架发生断裂。通过 ETD 断裂数据可以清楚地定位糖基化位点。通过 CID 进行糖基化结构阐明。CID 实验主要产生来自糖苷键断裂的片段离子,而不会打断肽键。与该方法不同的是,TMT 标记方案经过修改和调整,以提高标记效率,并使用 TriVersa NanoMate 重新注入样品,以改善糖肽的 ETD 和 HCD 谱。TMT 的定量是基于多个非糖肽和糖肽的 HCD 谱进行验证的。该方法可用于直接鉴定糖蛋白的定性和定量技术,并且可用于检测假冒糖蛋白药物产品。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验