To evaluate how interreader agreement and the site of the volume of interest (VOI) affect the agreement and variability of liver mean standardized uptake value normalized to lean body mass (SUL(mean)) at fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT).
Institutional review board approval was obtained for this HIPAA-compliant retrospective review of PET/CT images and patient records. PET/CT images were reviewed in 116 randomly selected patients who had undergone a baseline PET/CT examination and who had normal livers according to imaging and biochemical test results. A 30-mm-diameter spherical VOI was placed within the right lobe of the liver above, below, and at the level of the main portal vein. Two readers performed all measurements independently. Analysis of variance, intraclass correlation coefficient (ICC) analysis, and Bland-Altman analysis were performed.
The mean SUL(mean) was between 2.11 and 2.17 at the upper, portal, and lower levels of the right lobe of the liver. The coefficient of variance was between 21.0% and 23.1%, without significant differences for location, with the least variance in the upper level. The ICC of the two readers varied between 0.98 and 0.99 (95% confidence interval [CI]: 0.97, 0.99; P = .0001) at each level. The greatest precision (narrowest CI) was also in the upper level. Bias was 0.025 ± 0.10 (standard deviation) at the upper level, was 0.004 ± 0.14 at the lower level, and was 0.047 ± 0.10 at the portal vein (P = .02). For each reader, there was almost perfect reliability between the SUL(mean) measurements made at the three levels, with an ICC of 0.98 (95% CI: 0.98, 0.99; P = .0001).
Liver SUL(mean) at FDG PET/CT has excellent interreader agreement, with similar values and variance whether measured at the upper, lower, or portal vein levels within the right lobe of the liver.
评估读者间一致性和感兴趣区(VOI)位置如何影响氟 18 氟脱氧葡萄糖(FDG)正电子发射断层扫描(PET)/计算机断层扫描(CT)中肝脏标准化摄取值与去脂体重比值(SUL(mean))的一致性和变异性。
本 HIPAA 合规性回顾性研究回顾了 116 名随机选择的患者的 PET/CT 图像和患者记录,这些患者的 PET/CT 检查结果显示肝脏正常,且影像学和生化检查结果正常。在右肝叶上方、下方和主门静脉水平放置一个 30 毫米直径的球形 VOI。两名读者独立进行所有测量。进行方差分析、组内相关系数(ICC)分析和 Bland-Altman 分析。
右肝叶上、中、下水平的 SUL(mean)值在 2.11 到 2.17 之间。方差系数在 21.0%到 23.1%之间,位置之间无显著差异,上水平的方差最小。两名读者的 ICC 在每个水平的范围为 0.98 到 0.99(95%置信区间[CI]:0.97,0.99;P =.0001)。最高的精度(最窄的 CI)也在上水平。在上水平,偏差为 0.025±0.10(标准差),在下水平为 0.004±0.14,在门静脉水平为 0.047±0.10(P =.02)。对于每个读者,在右肝叶的三个水平上进行的 SUL(mean)测量之间几乎具有完美的可靠性,ICC 为 0.98(95%CI:0.98,0.99;P =.0001)。
FDG PET/CT 中的肝脏 SUL(mean)具有出色的读者间一致性,无论在右肝叶的上、下或门静脉水平测量,其值和变异性相似。