Suppr超能文献

通过F-FDG PET/CT对癌症治疗反应进行定量分析:测量变异性的多中心评估

Quantitation of Cancer Treatment Response by F-FDG PET/CT: Multicenter Assessment of Measurement Variability.

作者信息

O Joo Hyun, Jacene Heather, Luber Brandon, Wang Hao, Huynh Minh-Huy, Leal Jeffrey P, Wahl Richard L

机构信息

Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland.

Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.

出版信息

J Nucl Med. 2017 Sep;58(9):1429-1434. doi: 10.2967/jnumed.117.189605. Epub 2017 Mar 30.

Abstract

The aim of this study was to assess the interobserver variability of quantitative F-FDG PET/CT parameters used in assessments of treatment response across multiple sites and readers. Paired pre- and posttreatment F-FDG PET/CT images of 30 oncologic patients were distributed to 22 readers across 15 U.S. and international sites. One reader was aware of the full medical history (read) of the patients, whereas the 21 other readers were unaware. The readers selected the single hottest tumor from each study, and made SUV measurements from this target lesion and the liver. Descriptive statistics, percentage changes in the measurements, and their agreements were obtained. The intraclass correlation coefficient for the percentage change in SUV (%ΔSUV) of the hottest tumor was 0.894 (95% confidence interval [CI], 0.813-0.941), and the individual equivalence coefficient was 1.931 (95% CI, 0.568-6.449) when all reads were included ( = 638). When only the measurements that selected the same target tumor as the read ( = 486) were included, the intraclass correlation coefficient for the %ΔSUV was 0.944 (95% CI, 0.841-0.989), and the individual equivalence coefficient was -0.688 (95% CI, -1.810 to -0.092). The absolute change in SUV of liver corrected for lean body mass showed upper and lower limits of agreement (average bias ± 2 SDs) of 0.13 and -0.13 g/mL. The quantitative tumor SUV changes measured across multiple sites and readers show a high correlation. Selection of the same tumor target among readers further increased the degree of correlation.

摘要

本研究的目的是评估在多个机构和阅片者对治疗反应评估中使用的定量F-FDG PET/CT参数的观察者间变异性。30例肿瘤患者治疗前和治疗后的配对F-FDG PET/CT图像被分发给美国和国际15个机构的22位阅片者。其中一位阅片者知晓患者的完整病史(阅片者1),而其他21位阅片者不知情。阅片者从每项研究中选择单个最热点肿瘤,并对该靶病变和肝脏进行SUV测量。获得描述性统计数据、测量值的百分比变化及其一致性。当纳入所有读数(n = 638)时,最热点肿瘤SUV百分比变化(%ΔSUV)的组内相关系数为0.894(95%置信区间[CI],0.813 - 0.941),个体等效系数为1.931(95%CI,0.568 - 6.449)。当仅纳入与阅片者1选择相同靶肿瘤的测量值(n = 486)时,%ΔSUV的组内相关系数为0.944(95%CI,0.841 - 0.989),个体等效系数为 -0.688(95%CI,-1.810至 -0.092)。校正瘦体重后的肝脏SUV绝对变化显示一致性的上限和下限(平均偏差±2个标准差)为0.13和 -0.13 g/mL。在多个机构和阅片者间测量的定量肿瘤SUV变化显示出高度相关性。阅片者间选择相同的肿瘤靶标进一步提高了相关程度。

相似文献

引用本文的文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验