亲水性丙烯酸酯人工晶状体迟发性混浊:102 例患者随机抽样 87 眼分析。

Late opacification in hydrophilic acrylic intraocular lenses: analysis of 87 eyes in a random sample of 102 patients.

机构信息

Altino Ventura Foundation, Recife, Brazil.

出版信息

J Cataract Refract Surg. 2013 Mar;39(3):403-7. doi: 10.1016/j.jcrs.2012.09.023. Epub 2013 Jan 11.

Abstract

PURPOSE

To report the incidence of late postoperative opacification of a hydrophilic acrylic foldable intraocular lens (IOL).

SETTING

Altino Ventura Foundation, Pernambuco, Brazil.

DESIGN

Cross-sectional study.

METHODS

Patients were examined 4 years after phacoemulsification with Ioflex IOL implantation in the rural areas of Pernambuco, Brazil, as part of a community campaign for underprivileged people. The patients had a detailed ophthalmic examination to detect late IOL opacification. The patients' charts were reviewed for preexisting ocular pathology and corrected distance visual acuity (CDVA) before and 1 month after surgery. The IOL opacification was classified according to its location and severity.

RESULTS

All surgeries were uneventful intraoperatively and postoperatively. Six (7%) of the 87 eyes (58 patients) examined had a diagnosis of late IOL opacification; asteroid hyalosis and high myopia were associated ocular findings in 2 of the eyes. The preoperative CDVA ranged from hand motions (HM) to 20/80. The postoperative CDVA ranged from 20/20 to 20/40 except in 1 eye with posterior segment disease. Over the 4-year follow-up, 2 of the 6 eyes had a decrease in visual acuity to HM and 20/80, respectively, as a result of late IOL opacification. They had IOL replacement and CDVA improved to 20/60 and 20/20, respectively. A third eye with severe late opacification was not referred for IOL replacement because of macular disease.

CONCLUSION

Intraocular lens opacification was observed in 7% of the eyes studied. No risk factors could be determined.

摘要

目的

报告亲水丙烯酸可折叠人工晶状体(IOL)术后晚期混浊的发生率。

地点

巴西伯南布哥州阿尔蒂诺·文图拉基金会。

设计

横断面研究。

方法

在巴西伯南布哥州农村地区,作为为贫困人群开展的社区活动的一部分,对接受过超声乳化白内障吸除术联合 Ioflex IOL 植入术的患者进行了 4 年的随访。对患者进行了详细的眼科检查,以发现晚期 IOL 混浊。回顾了患者的病历,以了解术前眼部疾病和手术前后的矫正远视力(CDVA)。根据混浊的位置和严重程度对 IOL 混浊进行分类。

结果

所有手术均顺利进行。在 87 只眼(58 例患者)中,有 6 只(7%)诊断为晚期 IOL 混浊;其中 2 只眼伴有星状玻璃体混浊和高度近视。术前 CDVA 范围为手动(HM)至 20/80。术后 CDVA 范围为 20/20 至 20/40,除了 1 只眼有后节疾病。在 4 年的随访中,6 只眼中有 2 只(33%)因 IOL 混浊导致视力下降至 HM 和 20/80,分别进行了 IOL 置换术,术后 CDVA 分别提高至 20/60 和 20/20。另一只眼因黄斑病变严重混浊而未行 IOL 置换术。

结论

在研究的眼中,7%观察到 IOL 混浊。无法确定任何危险因素。