Suppr超能文献

采用新型径向 k 空间采样序列和平衡稳态自由进动对比模式的无需心电图同步的自由呼吸状态下的真正实时心脏 MRI。

True real-time cardiac MRI in free breathing without ECG synchronization using a novel sequence with radial k-space sampling and balanced SSFP contrast mode.

机构信息

Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23 C UG, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany.

出版信息

Int J Cardiovasc Imaging. 2013 Jun;29(5):1059-67. doi: 10.1007/s10554-013-0183-0. Epub 2013 Jan 19.

Abstract

We investigated a novel sequence with radial k-space sampling, gridding and sliding window reconstruction with bSSFP contrast that allows for true real-time functional cardiac evaluation independent from respiration and ECG triggering. 12 healthy volunteers underwent 1.5 T cardiac MRI. Single-shot short axis views were acquired with a) standard retrospectively ECG-gated segmented breath-hold (bh) bSSFP and with the real-time radial bSSFP sequence with a nominal temporal resolution of b) 16 fps (frames per second) and c) 40 fps. Radial bSSFP were acquired during free breathing without ECG synchronization. Left ventricular functional parameters (EDV, ESV, SV and EF) were compared and quality of wall motion depiction was assessed. Contrast-to-noise-ratio (CNR) of myocardium/blood pool in the left ventricle was calculated. EF showed excellent correlation (Bland-Altman r = 0.99; Lin rho = 0.91) between bh-bSSFP (65%) and 40 fps radial (64%) and moderate correlation (r = 0.84, rho = 0.20) with 16 fps radial bSSFP (56%). While EDV was in good agreement for all three sequences, ESV was significantly overestimated with 16 fps radial bSSFP. Despite lower CNR, image quality for wall motion assessment was rated significantly better for 40 fps compared to 16 fps radial bSSFP due to the faster temporal resolution. Left ventricular functional analysis with fast true real-time radial bSSFP is in good agreement with standard ECG-gated bh-bSSFP. The independency from ECG synchronization and breathing promises a robust method for patients with impaired cardiopulmonary status in whom breath-hold and good quality ECG cannot be achieved.

摘要

我们研究了一种具有径向 k 空间采样、网格和滑动窗口重建的新序列,该序列具有 bSSFP 对比,可以实现真正的实时功能心脏评估,与呼吸和 ECG 触发无关。12 名健康志愿者接受了 1.5T 心脏 MRI 检查。使用 a) 标准回顾性 ECG 门控分段屏气 (bh) bSSFP 和 b) 16 fps(每秒帧数)和 c) 40 fps 的实时径向 bSSFP 序列采集单次短轴视图。径向 bSSFP 在没有 ECG 同步的情况下在自由呼吸期间采集。比较左心室功能参数(EDV、ESV、SV 和 EF),评估壁运动描绘质量。计算左心室心肌/血池的对比噪声比 (CNR)。EF 在 bh-bSSFP(65%)和 40 fps 径向(64%)之间具有极好的相关性(Bland-Altman r = 0.99;Lin rho = 0.91),与 16 fps 径向 bSSFP(56%)具有中度相关性(r = 0.84,rho = 0.20)。虽然所有三种序列的 EDV 都非常吻合,但 16 fps 径向 bSSFP 明显高估了 ESV。尽管 CNR 较低,但由于时间分辨率较高,40 fps 径向 bSSFP 的壁运动评估图像质量评分明显优于 16 fps 径向 bSSFP。快速真正实时径向 bSSFP 的左心室功能分析与标准 ECG 门控 bh-bSSFP 非常吻合。独立于 ECG 同步和呼吸的特点使其成为心肺功能受损患者的一种可靠方法,这些患者无法屏气和获得高质量的 ECG。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验