Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

机构信息

Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, SA, Australia.

出版信息

Clin Orthop Relat Res. 2013 Jul;471(7):2238-44. doi: 10.1007/s11999-013-2789-x. Epub 2013 Jan 19.

Abstract

BACKGROUND

One cross-linked polyethylene (XLPE) liner is manufactured using a lower dose of radiation, 5 Mrad, which may result in less cross-linking. The reported in vivo wear rate of this XLPE liner in patients undergoing THA has varied, and has included some patients in each reported cohort who had greater than 0.1 mm/year of wear, which is an historical threshold for osteolysis. Previous studies have measured wear on plain radiographs, an approach that has limited sensitivity.

QUESTIONS/PURPOSES: We therefore measured the amount and direction of wear at 6 years using Radiostereometric analysis (RSA) in patients who had THAs that included a cross-linked polyethylene liner manufactured using 5 Mrad radiation.

METHODS

We prospectively reviewed wear in 30 patients who underwent primary THAs with the same design of cross-linked acetabular liner and a 28-mm articulation. Tantalum markers were inserted during surgery and all patients had RSA radiographic examinations at 1 week, 6 months, 1, 2, and 6 years postoperatively.

RESULTS

The mean proximal, two-dimensional (2-D) and three-dimensional (3-D) wear rates calculated between 1 year and 6 years were 0.014, 0.014, and 0.018 mm/per year, respectively. The direction of the head penetration recorded between 1 week and 6 years was in a proximal direction for all patients, proximolateral for 16 of 24 patients, and proximomedial for eight of 24 patients.

CONCLUSIONS

The proximal, 2-D and 3-D wear of a XLPE liner produced using 5 Mrad of radiation was low but measurable by RSA after 6 years. No patients had proximal 2-D or 3-D wear rates exceeding 0.1 mm/year. Further followup is needed to evaluate the effect of XLPE wear particles on the development of long-term osteolysis.

摘要

背景

一种交联聚乙烯(XLPE)衬垫采用较低剂量的辐射(5 Mrad)制造,这可能导致交联程度降低。接受全髋关节置换术(THA)的患者中,这种 XLPE 衬垫的报告体内磨损率各不相同,每个报告队列中都有一些患者的磨损率超过 0.1 毫米/年,这是骨溶解的历史阈值。以前的研究使用普通射线照相术测量磨损,这种方法的灵敏度有限。

问题/目的:因此,我们使用放射立体测量分析(RSA)测量了接受使用 5 Mrad 辐射制造的交联聚乙烯衬垫的 THA 的 6 年后的磨损量和方向。

方法

我们前瞻性地回顾了 30 名接受初次 THA 的患者的磨损情况,这些患者采用相同设计的交联髋臼衬垫和 28 毫米关节。手术期间插入钽标记物,所有患者在术后 1 周、6 个月、1 年、2 年和 6 年接受 RSA 放射照相检查。

结果

在 1 年至 6 年之间计算的近端、二维(2-D)和三维(3-D)磨损率平均值分别为 0.014、0.014 和 0.018 毫米/年。在 1 周到 6 年之间记录的头穿透方向对于所有患者均为近端,对于 24 名患者中的 16 名患者为近侧前外侧,对于 24 名患者中的 8 名患者为近侧内侧。

结论

使用 5 Mrad 辐射制造的 XLPE 衬垫的近端、2-D 和 3-D 磨损率较低,但在 6 年后通过 RSA 可测量。没有患者的近端 2-D 或 3-D 磨损率超过 0.1 毫米/年。需要进一步随访以评估 XLPE 磨损颗粒对长期骨溶解发展的影响。

相似文献

1
Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.
Clin Orthop Relat Res. 2013 Jul;471(7):2238-44. doi: 10.1007/s11999-013-2789-x. Epub 2013 Jan 19.
2
Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study.
Clin Orthop Relat Res. 2013 Nov;471(11):3596-600. doi: 10.1007/s11999-013-3188-z. Epub 2013 Jul 27.
3
What is the Long-term Wear of a 5-Mrad Highly Crosslinked Polyethylene Liner? A 14-year RSA Study.
Clin Orthop Relat Res. 2024 Oct 1;482(10):1789-1797. doi: 10.1097/CORR.0000000000003047. Epub 2024 Mar 28.
5
Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study.
Clin Orthop Relat Res. 2022 Mar 1;480(3):485-491. doi: 10.1097/CORR.0000000000002002.
7
Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.
Clin Orthop Relat Res. 2016 Feb;474(2):365-71. doi: 10.1007/s11999-015-4319-5.
8
Second-generation highly cross-linked X3™ polyethylene wear: a preliminary radiostereometric analysis study.
Clin Orthop Relat Res. 2010 Oct;468(10):2704-9. doi: 10.1007/s11999-010-1259-y. Epub 2010 Feb 12.
10
The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.
Clin Orthop Relat Res. 2012 Feb;470(2):462-70. doi: 10.1007/s11999-011-2052-2.

引用本文的文献

1
Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups.
Med Eng Phys. 2017 Sep;47:159-166. doi: 10.1016/j.medengphy.2017.06.005. Epub 2017 Jul 3.
3
Wear of highly crosslinked polyethylene acetabular components.
Acta Orthop. 2015 Apr;86(2):159-68. doi: 10.3109/17453674.2014.972890. Epub 2014 Oct 10.
4
Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study.
Clin Orthop Relat Res. 2013 Nov;471(11):3596-600. doi: 10.1007/s11999-013-3188-z. Epub 2013 Jul 27.

本文引用的文献

1
A prospective, randomized study of cross-linked and non-cross-linked polyethylene for total hip arthroplasty at 10-year follow-up.
J Arthroplasty. 2012 Sep;27(8 Suppl):2-7.e1. doi: 10.1016/j.arth.2012.03.048. Epub 2012 Jun 6.
4
Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.
Clin Orthop Relat Res. 2010 Dec;468(12):3228-33. doi: 10.1007/s11999-010-1379-4.
6
How has the biologic reaction to wear particles changed with newer bearing surfaces?
J Am Acad Orthop Surg. 2008;16 Suppl 1:S49-55. doi: 10.5435/00124635-200800001-00011.
8
Highly crosslinked vs conventional polyethylene particles: relative in vivo inflammatory response.
J Arthroplasty. 2009 Jan;24(1):117-24. doi: 10.1016/j.arth.2008.01.134. Epub 2008 Apr 10.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验