磁致伸缩与压电超声洁治设备的比较:一项体外研究。

A comparison of magnetostrictive and piezoelectric ultrasonic scaling devices: an in vitro study.

作者信息

Yousefimanesh Hojatollah, Robati Maryam, Kadkhodazadeh Mahdi, Molla Reza

机构信息

Department of Periodontology, Ahvaz Jundishapur University of Medical Sciences Faculty of Dentistry, Ahwaz, Iran.

出版信息

J Periodontal Implant Sci. 2012 Dec;42(6):243-7. doi: 10.5051/jpis.2012.42.6.243. Epub 2012 Dec 31.

Abstract

PURPOSE

The effects of magnetostrictive and piezoelectric devices on tooth surfaces seem to differ with regard to the root surface roughness they produce. This study aimed to compare the results of scaling using magnetostrictive and piezoelectric devices on extracted teeth.

METHODS

Forty-four human extracted teeth were assigned to four study groups (n=11). In two groups (C100 and C200), the teeth were scaled using a magnetostrictive device and two different lateral forces: 100 g and 200 g, respectively. In the other two groups (P100 and P200), the teeth were scaled with a piezoelectric device with 100 g and 200 g of lateral force, respectively. he teeth were scaled and the data on the duration of scaling and the amount of surface were collected and analyzed using the t-test.

RESULTS

The mean time needed for instrumentation for the piezoelectric and magnetostrictive devices was 50:54 and 41:10, respectively, but their difference was not statistically significant (P=0.171). For root surface roughness, we only found a statistically significantly poorer result for the C200 group in comparison to the P200 group (P=0.033).

CONCLUSIONS

This study revealed that applying a piezoelectric scaler with 200 g of lateral force leaves smoother surfaces than a magnetostrictive device with the same lateral force.

摘要

目的

磁致伸缩装置和压电装置对牙齿表面的影响在它们所产生的牙根表面粗糙度方面似乎有所不同。本研究旨在比较使用磁致伸缩装置和压电装置对拔除牙齿进行洁治的结果。

方法

44颗人类拔除牙齿被分配到四个研究组(n = 11)。在两组(C100和C200)中,分别使用磁致伸缩装置和两种不同的侧向力(100 g和200 g)对牙齿进行洁治。在另外两组(P100和P200)中,分别使用侧向力为100 g和200 g的压电装置对牙齿进行洁治。对牙齿进行洁治,并收集洁治持续时间和表面量的数据,使用t检验进行分析。

结果

压电装置和磁致伸缩装置进行器械操作所需的平均时间分别为50:54和41:10,但它们的差异无统计学意义(P = 0.171)。对于牙根表面粗糙度,我们仅发现C200组与P200组相比结果在统计学上显著较差(P = 0.033)。

结论

本研究表明,施加200 g侧向力的压电洁治器比施加相同侧向力的磁致伸缩装置能使表面更光滑。