Suppr超能文献

通过磁共振成像测量发现色素性视网膜炎患者视网膜 - 脉络膜血流减少。

Decreased retinal-choroidal blood flow in retinitis pigmentosa as measured by MRI.

作者信息

Zhang Yi, Harrison Joseph M, Nateras Oscar San Emeterio, Chalfin Steven, Duong Timothy Q

机构信息

Research Imaging Institute, University of Texas Health Science Center, 8403 Floyd Curl Dr, San Antonio, TX 78229, USA.

出版信息

Doc Ophthalmol. 2013 Jun;126(3):187-97. doi: 10.1007/s10633-013-9374-1. Epub 2013 Feb 14.

Abstract

PURPOSE

To evaluate retinal and choroidal blood flow (BF) using high-resolution magnetic resonance imaging (MRI) as well as visual function measured by the electroretinogram (ERG) in patients with retinitis pigmentosa (RP).

METHODS

MRI studies were performed in 6 RP patients (29-67 years) and 5 healthy volunteers (29-64 years) on a 3-Tesla scanner with a custom-made surface coil. Quantitative BF was measured using the pseudo-continuous arterial spin-labeling technique at 0.5 × 0.8 × 6.0 mm. Full-field ERGs of all patients were recorded. Amplitudes and implicit times of standard ERGs were analyzed.

RESULTS

Basal BF in the posterior retinal-choroid was 142 ± 16 ml/100ml/min (or 1.14 ± 0.13 μl/mm(2)/min) in the control group and was 70 ±19 ml/100ml/min (or 0.56 ± 0.15 μl/mm(2)/min) in the RP group. Retinal-choroidal BF was significantly reduced by 52 ± 8 % in RP patients compared to controls (P<0.05). ERG a- and b-wave amplitudes of RP patients were reduced, and b-wave implicit times were delayed. There were statistically significant correlations between a-wave amplitude and BF value (r=0.9, P<0.05) but not between b-wave amplitude and BF value (r =0.7, P=0.2).

CONCLUSIONS

This study demonstrates a novel non-invasive MRI approach to measure quantitative retinal and choroidal BF in RP patients. We found that retinal-choroidal BF was markedly reduced and significantly correlated with reduced amplitudes of the a-wave of the standard combined ERG.

摘要

目的

使用高分辨率磁共振成像(MRI)评估视网膜色素变性(RP)患者的视网膜和脉络膜血流(BF),并通过视网膜电图(ERG)测量视觉功能。

方法

对6例RP患者(29 - 67岁)和5名健康志愿者(29 - 64岁)使用定制表面线圈在3特斯拉扫描仪上进行MRI研究。采用伪连续动脉自旋标记技术在0.5×0.8×6.0 mm处测量定量BF。记录所有患者的全视野ERG。分析标准ERG的振幅和隐含时间。

结果

对照组视网膜 - 脉络膜后部的基础BF为142±16 ml/100ml/min(或1.14±0.13 μl/mm²/min),RP组为70±19 ml/100ml/min(或0.56±0.15 μl/mm²/min)。与对照组相比,RP患者的视网膜 - 脉络膜BF显著降低52±8%(P<0.05)。RP患者的ERG a波和b波振幅降低,b波隐含时间延迟。a波振幅与BF值之间存在统计学显著相关性(r = 0.9,P<0.05),但b波振幅与BF值之间无相关性(r = 0.7,P = 0.2)。

结论

本研究展示了一种测量RP患者视网膜和脉络膜定量BF的新型非侵入性MRI方法。我们发现视网膜 - 脉络膜BF显著降低,且与标准联合ERG的a波振幅降低显著相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d37d/3665727/3c5f4b35f5cd/nihms-445968-f0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验