Suppr超能文献

拉布拉多猎犬肢体周长人体测量评估的不同测试者间及同一测试者内的可靠性

Inter- and intratester reliability of anthropometric assessment of limb circumference in labrador retrievers.

作者信息

Smith Thomas J, Baltzer Wendy I, Jelinski Susan E, Salinardi Brenda J

机构信息

Department of Clinical Sciences, Oregon State University, Corvallis, OR, USA.

出版信息

Vet Surg. 2013 Apr;42(3):316-21. doi: 10.1111/j.1532-950X.2013.01102.x. Epub 2013 Mar 4.

Abstract

OBJECTIVE

To report a standardized method of, and determine inter- and intratester reliability for, anthropometric assessment of limb circumference in dogs.

STUDY DESIGN

Prospective blinded study.

ANIMALS

Labrador Retrievers (n = 20).

METHOD

Unsedated dogs were manually restrained in lateral recumbency and triplicate measurements of limb circumference at the level of the proximal antebrachium, mid brachium, proximal crus, and mid-thigh were made using the Gulick II tape measure in the morning and afternoon of the same day. Observers were blinded to measurements made during each occasion and those made by co-observers. Estimates of inter- and intratester reliability were made for first and mean measurements using intra-class correlation coefficients (ICC).

RESULTS

Measurements of the proximal antebrachium were made with moderate to fair intratester reliability by all observers with ICC's ranging from 0.68-0.78 (1st measurement) and 0.67-0.78 (mean measurement), and moderate to fair intertester reliability with ICC's of 0.66-0.68 (1st measurement) and 0.70-0.72 (mean measurement). Measurements of the brachium, crus, and thigh typically had poor inter- and intratester reliability, ICC < 0.5.

CONCLUSION

Using the described method of muscle measurement in Labrador Retrievers only measurement of the proximal antebrachium was reliable; a single (1st) measurement was as reliable as using the mean of triplicate measurements.

摘要

目的

报告一种标准化的犬类肢体周长人体测量方法,并确定测试者之间和测试者内部的可靠性。

研究设计

前瞻性盲法研究。

动物

拉布拉多寻回犬(n = 20)。

方法

未使用镇静剂的犬只被手动限制为侧卧姿势,在同一天的上午和下午,使用古利克二世卷尺在近端前臂、上臂中部、近端小腿和大腿中部水平对肢体周长进行三次重复测量。观察者对每次测量以及共同观察者所做的测量均不知情。使用组内相关系数(ICC)对首次测量和平均测量的测试者之间和测试者内部的可靠性进行估计。

结果

所有观察者对近端前臂的测量具有中等至良好的测试者内部可靠性,ICC范围为0.68 - 0.78(首次测量)和0.67 - 0.78(平均测量),测试者之间的可靠性为中等至良好,ICC为0.66 - 0.68(首次测量)和0.70 - 0.72(平均测量)。对上臂、小腿和大腿的测量通常具有较差的测试者之间和测试者内部可靠性,ICC < 0.5。

结论

使用所描述的拉布拉多寻回犬肌肉测量方法,仅近端前臂的测量是可靠的;单次(首次)测量与使用三次重复测量的平均值一样可靠。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验