Suppr超能文献

使用高度多孔钛杯进行初次全髋关节置换术的出色结果。

Excellent results of primary THA using a highly porous titanium cup.

作者信息

Naziri Qais, Issa Kimona, Pivec Robert, Harwin Steven F, Delanois Ronald E, Mont Michael A

机构信息

Center for Joint Preservation and Reconstruction, Rubin Institute for Advanced Orthopedics, Sinai Hospital, Baltimore, MD 21215, USA.

出版信息

Orthopedics. 2013 Apr;36(4):e390-4. doi: 10.3928/01477447-20130327-10.

Abstract

Cementless acetabular cups for primary total hip arthroplasty have had excellent results, with failure rates typically less than 5% at up to 10-year follow-up. Tritanium is a 3-dimensional metal interface that has been used for porous biological fixation. The purpose of this study was to review the clinical and radiographic results of the use of Tritanium cups (Stryker Orthopaedics, Mahwah, New Jersey) for primary total hip arthroplasty. Two hundred eighty-eight total hip arthroplasties performed using a porous titanium acetabular cup in 252 patients between 2008 and 2010 were reviewed. One hundred thirty-three men and 119 women with a mean age of 58 years (range, 18-88 years) were included. Mean follow-up was 36 months (range, 24-56 months). Outcomes evaluated were implant survivorship, Harris Hip Score, complications, and radiographic outcomes. At final follow-up, no cup failures had occurred. Mean Harris Hip Score improved from 53 points (range, 33-82 points) preoperatively to 91 points (range, 64-100 points) postoperatively. One complication occurred; a 64-year-old woman with recurrent postoperative effusions underwent hip exploration and required abductor mechanism repair. On radiologic evaluation, no signs existed of progressive radiolucencies or changes in cup position. The survivorship of the Tritanium cup and the low complication rate is comparable with previous studies using other porous-metal prostheses. Longer follow-up study is needed and assessment of the results of using this implant in the revision setting is important.

摘要

用于初次全髋关节置换术的非骨水泥髋臼杯取得了优异的效果,在长达10年的随访中,失败率通常低于5%。Tritanium是一种三维金属界面,已用于多孔生物固定。本研究的目的是回顾使用Tritanium杯(史赛克骨科,新泽西州马哈瓦)进行初次全髋关节置换术的临床和影像学结果。回顾了2008年至2010年间在252例患者中使用多孔钛髋臼杯进行的288例全髋关节置换术。纳入了133名男性和119名女性,平均年龄58岁(范围18 - 88岁)。平均随访时间为36个月(范围24 - 56个月)。评估的结果包括植入物存活率、Harris髋关节评分、并发症和影像学结果。在最后随访时,未发生髋臼杯失败。Harris髋关节评分平均从术前的53分(范围33 - 82分)提高到术后的91分(范围64 - 100分)。发生了1例并发症;一名64岁女性术后反复出现积液,接受了髋关节探查,需要修复外展肌机制。在影像学评估中,没有进行性透亮区或髋臼杯位置改变的迹象。Tritanium杯的存活率和低并发症率与先前使用其他多孔金属假体的研究相当。需要更长时间的随访研究,并且评估在翻修情况下使用这种植入物的结果很重要。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验