Suppr超能文献

使用直接能量沉积制造的3D打印髋臼杯进行无水泥全髋关节置换术的短期结果:一项前瞻性观察研究。

Short-Term Outcomes of Cementless Total Hip Arthroplasty Using a 3D-Printed Acetabular Cup Manufactured by Directed Energy Deposition: A Prospective Observational Study.

作者信息

Bahk Ji Hoon, Jo Woo-Lam, Lee Kee-Haeng, Song Joo-Hyoun, Kim Seung-Chan, Lim Young Wook

机构信息

Department of Orthopedic Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.

Department of Orthopedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.

出版信息

J Clin Med. 2025 Jun 26;14(13):4527. doi: 10.3390/jcm14134527.

Abstract

: Additive manufacturing (AM) enables the production of cementless acetabular cups with porous surfaces that facilitate early osseointegration. Directed energy deposition (DED), a form of AM, allows the direct welding of porous structures onto metal substrates without requiring a vacuum environment, offering advantages over conventional powder bed fusion methods. Despite growing interest in DED, no prospective clinical studies evaluating DED-based acetabular components have been published to date. This study assessed short-term outcomes of a DED-based 3D-printed acetabular cup in total hip arthroplasty (THA). : A total of 120 patients who underwent primary cementless THA using the Corentec Mirabo Z acetabular cup were prospectively enrolled. Among them, 124 hips from 100 patients who had completed a minimum of 24 months of follow-up were included in the analysis. Clinical outcomes were assessed using the Harris hip score (HHS), WOMAC, EQ-5D-5L, and pain NRS. Radiographic evaluation included measurements of cup position, osseointegration, and detection of interfacial or polar gaps on CT and plain radiographs. Implant-related complications were also recorded. : At a mean follow-up of 34.6 months, the implant survival rate was 99.3%, with one revision due to suspected osseointegration failure. The HHS improved from 56.6 to 91.4 at 24 months, and the NRS decreased from 6.2 to 1.1 (both < 0.001). Interfacial gaps were observed in 58.1% of cases on CT, though most were <1 mm and not clinically significant. Common postoperative issues included greater trochanteric pain syndrome, squeaking, and iliotibial band tightness, all of which were resolved with conservative treatment. : DED-based 3D-printed acetabular cups demonstrated favorable short-term clinical and radiographic outcomes, with high survivorship and reliable early osseointegration in cementless THA.

摘要

增材制造(AM)能够生产具有多孔表面的非骨水泥髋臼杯,这有助于早期骨整合。定向能量沉积(DED)作为增材制造的一种形式,可在无需真空环境的情况下将多孔结构直接焊接到金属基板上,相较于传统的粉末床熔融方法具有优势。尽管人们对DED的兴趣日益浓厚,但迄今为止,尚未发表评估基于DED的髋臼组件的前瞻性临床研究。本研究评估了在全髋关节置换术(THA)中基于DED的3D打印髋臼杯的短期结果。

共有120例患者前瞻性纳入研究,这些患者接受了使用Corentec Mirabo Z髋臼杯的初次非骨水泥THA。其中,对100例患者的124个髋关节进行了分析,这些患者至少完成了24个月的随访。使用Harris髋关节评分(HHS)、WOMAC、EQ - 5D - 5L和疼痛数字评定量表(NRS)评估临床结果。影像学评估包括髋臼杯位置测量、骨整合情况以及在CT和平片上检测界面或极间间隙。还记录了与植入物相关的并发症。

在平均34.6个月的随访中,植入物生存率为99.3%,有一例因疑似骨整合失败而翻修。HHS在24个月时从56.6提高到91.4,NRS从6.2降至1.1(均P < 0.001)。CT检查发现58.1%的病例存在界面间隙,不过大多数间隙<1 mm,无临床意义。常见的术后问题包括大转子疼痛综合征、弹响和髂胫束紧张,所有这些问题均通过保守治疗得到解决。

基于DED的3D打印髋臼杯在非骨水泥THA中显示出良好的短期临床和影像学结果,具有高生存率和可靠的早期骨整合。