Familiari Filippo, Barone Alessandro, De Gori Marco, Banci Lorenzo, Palco Michelangelo, Simonetta Roberto, Gasparini Giorgio, Mercurio Michele, Calafiore Giuseppe
Department of Orthopaedic and Trauma Surgery, Magna Graecia University, 88100 Catanzaro, Italy.
Research Center on Musculoskeletal Health, MusculoSkeletalHealth@UMG, Magna Graecia University, 88100 Catanzaro, Italy.
J Clin Med. 2024 Feb 8;13(4):969. doi: 10.3390/jcm13040969.
(1) : The aim of this study was to evaluate short- to mid-term clinical and radiological results in patients undergoing primary total hip arthroplasty (THA) with the use of a Selective Laser Melting 3D-printed highly porous titanium acetabular cup (Jump System Traser, Permedica Orthopaedics). (2) : We conducted a retrospective study and collected prospective data on 125 consecutive patients who underwent primary THA with the use of highly porous titanium cup. Each patient was evaluated preoperatively and postoperatively with a clinical and radiological assessment. (3) : The final cohort consisted of 104 patients evaluated after a correct value of 52 (38-74) months. The median Harris Hip Score (HHS) significantly improved from 63.7 (16-95.8) preoperatively to 94.8 (38.2-95.8) postoperatively ( < 0.001), with higher improvement associated with higher age at surgery (β = 0.22, = 0.025). On postoperative radiographs, the average acetabular cup inclination and anteversion were 46° (30°-57°) and 15° (1°-32°), respectively. All cups radiographically showed signs of osseointegration with no radiolucency observed, or component loosening. (4) : The use of this highly porous acetabular cup in primary THA achieved excellent clinical, functional, and radiological results at mid-term follow-up. A better clinical recovery can be expected in older patients. The radiological evaluation showed excellent osseointegration of the cup with complete absence of periprosthetic radiolucent lines.
(1):本研究的目的是评估使用选择性激光熔化3D打印的高度多孔钛髋臼杯(Jump System Traser,Permedica Orthopaedics)进行初次全髋关节置换术(THA)患者的短期至中期临床和放射学结果。(2):我们进行了一项回顾性研究,并收集了125例连续使用高度多孔钛杯进行初次THA患者的前瞻性数据。每位患者在术前和术后均接受临床和放射学评估。(3):最终队列由104例患者组成,在平均52(38 - 74)个月的随访后进行评估。Harris髋关节评分(HHS)中位数从术前的63.7(16 - 95.8)显著提高到术后的94.8(38.2 - 95.8)(<0.001),手术年龄越大改善越明显(β = 0.22,P = 0.025)。术后X线片显示,髋臼杯平均倾斜度和前倾角分别为46°(30° - 57°)和15°(1° - 32°)。所有髋臼杯在X线片上均显示骨整合迹象,未观察到透光线或假体松动。(4):在初次THA中使用这种高度多孔髋臼杯在中期随访时取得了优异的临床、功能和放射学结果。老年患者有望获得更好的临床恢复。放射学评估显示髋臼杯骨整合良好,假体周围完全没有透光线。