Kaner Doğan, Zhao Han, Terheyden Hendrik, Friedmann Anton
Department of Periodontology, University of Witten/Herdecke, Witten, Germany.
Clin Oral Implants Res. 2014 Jul;25(7):867-70. doi: 10.1111/clr.12158. Epub 2013 Apr 18.
To investigate the effect of submucosal implantation of self-filling osmotic tissue expanders on mucosal microcirculation.
In ten beagle dogs, all premolars were extracted on both sides of the mandible. Tooth-supporting bone and excess soft tissue were removed to mimic a severely resorbed edentulous ridge. Six weeks later, tissue expanders with 0.7 ml final volume were implanted into a submucosal pouch at randomly selected test sites, while contralateral sites served as untreated controls. Microcirculation was assessed in perfusion units (PU) before surgery, after local anaesthesia, directly after surgery, and after 1 and 3 days, using Laser Doppler flowmetry.
Local anaesthesia caused a significant decrease of blood flow from baseline (zero) to -6.4 PU (median; Q1 -10.5; Q3 -0.9; P = 0.006); however, no additional significant decrease was recorded after completion of surgery. Blood flow showed significant increases to -3.6 PU (median; Q1 -11.3, Q3 2.1; P = 0.02) and -4.0 PU (median; Q1 -9.2, Q3 1.1; P = 0.013) after 1 and 3 days, respectively, when compared to the measurements obtained after application of local anaesthesia and completion of surgery. Blood flow had returned to unimpaired baseline levels 1 day after surgery (P > 0.05).
Submucosal implantation of self-filling osmotic tissue expanders results in only momentary disturbance of microcirculation. The minor impairment of perfusion may explain the consistently good outcomes of submucosal implantation of these tissue expanders.
研究自填充渗透式组织扩张器黏膜下植入对黏膜微循环的影响。
选取10只比格犬,拔除双侧下颌所有前磨牙。去除支持牙齿的骨组织和多余软组织,模拟严重吸收的无牙颌骨嵴。六周后,将最终体积为0.7毫升的组织扩张器植入随机选择的测试部位的黏膜下袋中,对侧部位作为未处理的对照。使用激光多普勒血流仪在手术前、局部麻醉后、手术后即刻以及术后1天和3天评估微循环,以灌注单位(PU)表示。
局部麻醉导致血流从基线(零)显著下降至-6.4 PU(中位数;四分位数间距Q1为-10.5;Q3为-0.9;P = 0.006);然而,手术完成后未记录到额外的显著下降。与局部麻醉后和手术完成后的测量值相比,血流在术后1天和3天分别显著增加至-3.6 PU(中位数;Q1为-11.3,Q3为2.1;P = 0.02)和-4.0 PU(中位数;Q1为-9.2,Q3为1.1;P = 0.013)。术后1天血流已恢复到未受影响的基线水平(P > 0.05)。
自填充渗透式组织扩张器黏膜下植入仅导致微循环的短暂干扰。灌注的轻微损害可能解释了这些组织扩张器黏膜下植入始终具有良好效果的原因。