Suppr超能文献

硅水凝胶镜片及护理液对角膜上皮通透性的影响。

Impact of silicone hydrogel lenses and solutions on corneal epithelial permeability.

作者信息

Duench Stephanie, Sorbara Luigina, Keir Nancy, Simpson Trefford, Jones Lyndon

机构信息

Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.

出版信息

Optom Vis Sci. 2013 Jun;90(6):546-56. doi: 10.1097/OPX.0b013e318294c2a6.

Abstract

PURPOSE

The primary purpose of this pilot study was to compare epithelial barrier function (EBF) and staining in a small group of participants using a silicone hydrogel (SH) lens worn on a daily basis with two different care regimens. Secondarily, the aim was to see if there was any correlation between corneal staining and EBF.

METHODS

The corneal EBF of 10 non-lens wearers (control) and 15 age-matched asymptomatic SH contact lens wearers (test) were assessed using fluorophotometry. Biomicroscopy was performed to assess corneal staining after the EBF was measured. The lens wearers wore PureVision (FDA group V) SH lenses for two consecutive 1-month periods while using either Alcon Opti-Free Express or Renu Fresh using a randomized, investigator-masked, crossover design. Control subjects were assessed on one occasion, and lens wearers were examined before fitting with lenses and after 7, 14, and 28 days of lens wear, with each combination.

RESULTS

Compared with the control group, both study groups had an increase in epithelial permeability at baseline (p ≤ 0.04). There were no changes in EBF during the treatment period for either solution (p = 0.87). A significant difference in EBF was found between the test groups during the treatment period (p = 0.02), with greater permeability in the Renu Fresh-disinfected lenses. There was poor correlation between corneal staining and EBF (r = 0.35, p > 0.05) because of large individual variations.

CONCLUSIONS

Daily wear of highly oxygen-permeable SH lenses increases corneal epithelial permeability to fluorescein probably because of increased mechanical effects. In addition, certain lens-solution interactions can add to this effect, as seen in this study. Despite having a low amount of central corneal staining in the Renu Fresh group, staining and EBF did not prove to be well correlated. The presence of central corneal staining is a confounding factor when measuring EBF.

摘要

目的

本初步研究的主要目的是比较一小群参与者使用每日佩戴的硅水凝胶(SH)镜片并采用两种不同护理方案时的上皮屏障功能(EBF)和染色情况。其次,目的是观察角膜染色与EBF之间是否存在任何相关性。

方法

使用荧光光度法评估10名非镜片佩戴者(对照组)和15名年龄匹配的无症状SH隐形眼镜佩戴者(测试组)的角膜EBF。在测量EBF后进行生物显微镜检查以评估角膜染色情况。镜片佩戴者连续两个1个月期间佩戴PureVision(FDA V类)SH镜片,同时使用爱尔康Opti-Free Express或润明Fresh,采用随机、研究者盲法、交叉设计。对照组受试者仅进行一次评估,镜片佩戴者在配镜前以及佩戴镜片7天、14天和28天后,对每种组合进行检查。

结果

与对照组相比,两个研究组在基线时上皮通透性均增加(p≤0.04)。两种溶液在治疗期间EBF均无变化(p = 0.87)。在治疗期间,测试组之间的EBF存在显著差异(p = 0.02),润明Fresh消毒镜片的通透性更高。由于个体差异较大,角膜染色与EBF之间的相关性较差(r = 0.35,p>0.05)。

结论

每日佩戴高透氧性的SH镜片可能由于机械作用增加而导致角膜上皮对荧光素的通透性增加。此外,如本研究所示,某些镜片与护理液的相互作用会加剧这种影响。尽管润明Fresh组中央角膜染色量较低,但染色与EBF并未显示出良好的相关性。在测量EBF时,中央角膜染色的存在是一个混杂因素。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验