Suppr超能文献

半刚性假体环是否会影响二尖瓣修复术后左心室功能?

Do semi-rigid prosthetic rings affect left ventricular function after mitral valve repair?

机构信息

Department of Cardiovascular Surgery, Teikyo University Hospital, Tokyo, Japan.

出版信息

Circ J. 2013;77(8):2038-42. doi: 10.1253/circj.cj-12-1600. Epub 2013 May 15.

Abstract

BACKGROUND

After reports of cardiac impairment caused by mitral annuloplasty with rigid rings, several prosthetic rings with semi-rigidity were introduced. The influence of semi-rigid rings on postoperative cardiac function remains unknown. This study compared postoperative cardiac function between patients receiving a semi-rigid prosthetic ring and those receiving a flexible ring or band.

METHODS AND RESULTS

Transthoracic echocardiographic data of 305 patients who underwent mitral valve repair for degenerative mitral regurgitation (227 patients receiving a semi-rigid ring and 78 receiving a flexible ring or band) were retrospectively reviewed. The imbalance in the preoperative characteristics between groups was adjusted with propensity score matching. Left ventricular ejection fraction, end-diastolic dimension, and end-systolic dimension were compared at 1 week, 6 months, and 1 year after surgery. Propensity score matching yielded 68 matched pairs of patients for whom there were few group differences in preoperative covariates. Between patients receiving a semi-rigid ring and those receiving a flexible ring or band in the propensity-matched cohorts, there were no significant differences in ejection fraction (P=0.322), end-diastolic dimension (P=0.576), or end-systolic dimension (P=0.567).

CONCLUSIONS

There was little difference in the influence on postoperative cardiac function between semi-rigid rings and flexible rings or bands.

摘要

背景

在报道了由硬性环二尖瓣成形术引起的心脏损伤后,引入了几种半刚性的人工环。半刚性环对术后心功能的影响尚不清楚。本研究比较了接受半刚性人工环与接受弹性环或带的患者术后心功能。

方法和结果

回顾性分析了 305 例退行性二尖瓣反流患者(227 例接受半刚性环,78 例接受弹性环或带)经胸超声心动图数据。采用倾向评分匹配调整组间术前特征的不平衡。比较术后 1 周、6 个月和 1 年左心室射血分数、舒张末期和收缩末期内径。倾向评分匹配产生了 68 对匹配的患者,这些患者的术前协变量差异很小。在倾向评分匹配队列中,接受半刚性环与接受弹性环或带的患者之间,射血分数(P=0.322)、舒张末期内径(P=0.576)或收缩末期内径(P=0.567)无显著差异。

结论

半刚性环与弹性环或带对术后心功能的影响差异不大。