The Medical Device Research Institute, Flinders University, GPO Box 2100, Adelaide, SA, 5001, Australia,
J Clin Monit Comput. 2013 Oct;27(5):577-85. doi: 10.1007/s10877-013-9473-2. Epub 2013 May 17.
Heart rate variability (HRV) analysis over shorter periods may be useful for monitoring dynamic changes in autonomic nervous system activity where steady-state conditions are not maintained (e.g. during drug administration, or the start or end of exercise). This study undertakes a validation of 70 HRV indices that have previously been identified as possible for short-term use. The indices were validated over 10 × 30 beat windows using PhysioNet databases with physiological states of rest, active, exercising, sleeping, and meditating (N from 12 to 20). Baseline 95 % confidence intervals of the median were established with bootstrap resampling (10,000x). Statistical significance was assessed using the overlap of 95 % confidence intervals. Thirty-one indices could differentiate between resting and at least one physiological state using 30 beat windows. All respiratory sinus arrhythmia indices and Poincaré plot indices were strongly correlated to time domain measures (SDNN or RMSSD). Spectral indices using the Lomb-Scargle algorithm were able to correctly identify paradoxical shifts in power with meditation and reduced power in exercise. Some less-known indices gave interesting results: PolVar20 identified the higher sympathetic activity of exercise with the largest positive magnitude. These indices should now be considered for rigorous gold standard tests with pharmacological blockade.
心率变异性(HRV)分析较短的时期可能是有用的监测自主神经系统活动的动态变化,在稳定状态没有得到维持(例如,在药物给药期间,或在开始或结束运动)。本研究验证了以前确定的 70 个可能用于短期使用的 HRV 指数。使用 PhysioNet 数据库,对 10×30 个心跳窗口的生理状态(休息、活跃、运动、睡眠和冥想)(N 从 12 到 20)进行了 70 个 HRV 指数的验证。使用 bootstrap 重采样(10,000 次)建立中位数的 95%置信区间的基线。使用 95%置信区间的重叠来评估统计学意义。31 个指数可以使用 30 个心跳窗口区分休息和至少一种生理状态。所有呼吸窦性心律失常指数和 Poincaré 图指数与时域测量(SDNN 或 RMSSD)都有很强的相关性。使用 Lomb-Scargle 算法的谱指数能够正确识别冥想时的功率反常转移和运动时的功率降低。一些不太知名的指数给出了有趣的结果:PolVar20 确定了运动时交感神经活动更高,幅度最大为正。这些指数现在应该考虑与药理学阻断进行严格的黄金标准测试。