Suppr超能文献

视频头脉冲试验在检测垂直半规管功能障碍中的应用。

Application of the video head impulse test to detect vertical semicircular canal dysfunction.

机构信息

Vestibular Research Laboratory, School of Psychology, University of Sydney, Sydney, Australia.

出版信息

Otol Neurotol. 2013 Aug;34(6):974-9. doi: 10.1097/MAO.0b013e31828d676d.

Abstract

OBJECTIVE

The video head impulse test (vHIT) is a useful clinical tool to detect semicircular canal dysfunction. However, so far, vHIT has been limited to measurement of the function of the horizontal semicircular canals. The goal of this study was to determine if vHIT can detect vertical semicircular canal dysfunction.

STUDY DESIGN

Horizontal and vertical eye movements were recorded in response to abrupt, passive, unpredictable head turns (head impulses) in the planes of the vertical semicircular canals by high-speed video (250-Hz sampling rate) together with measures of the head movement. Head impulses were delivered diagonally in the plane of the vertical semicircular canals, whereas gaze was directed along the same plane. Patients with known vestibular loss as shown by previous scleral search coil recording were tested to identify if the vHIT testing could detect the loss.

RESULTS

The results of patients with unilateral, bilateral, and individual semicircular canal dysfunction were compared with the results of a healthy control subject. The patient with bilateral vestibular loss had no compensatory slow eye movements in any direction. The patient with unilateral vestibular loss showed reduced response for head impulses activating the canals in their affected right ear (right anterior, right posterior, and right horizontal head impulses). The patient with isolated canal loss showed reduced response for head impulses activating the affected right posterior canal.

CONCLUSION

vHIT detects peripheral deficits of both vertical and horizontal semicircular canal function and is a new tool for measuring dysfunction of individual semicircular canals in vestibular patients.

摘要

目的

视频头脉冲测试(vHIT)是一种检测半规管功能障碍的有用临床工具。然而,到目前为止,vHIT 仅限于测量水平半规管的功能。本研究的目的是确定 vHIT 是否可以检测垂直半规管功能障碍。

研究设计

通过高速视频(250-Hz 采样率)记录水平和垂直眼球运动,以响应垂直半规管平面中突发、被动、不可预测的头部转动(头脉冲),同时测量头部运动。头脉冲以垂直半规管平面对角线方向传递,而注视方向与该平面一致。对先前通过巩膜搜索线圈记录已知前庭损失的患者进行测试,以确定 vHIT 测试是否可以检测到损失。

结果

将单侧、双侧和单个半规管功能障碍患者的结果与健康对照受试者的结果进行比较。双侧前庭损失患者在任何方向均无代偿性缓慢眼球运动。单侧前庭损失患者在其受影响的右耳(右前、右后和右水平头脉冲)激活的半规管头脉冲反应减少。孤立管损失患者在激活受影响的右后管的头脉冲反应减少。

结论

vHIT 可检测垂直和水平半规管功能的外周缺陷,是测量前庭患者单个半规管功能障碍的新工具。