Suppr超能文献

应用交叉小脑灌注减少检测慢性单侧大脑中动脉狭窄性病变患者的半球性低灌注:脑 SPECT 和 PET 成像比较。

Detection of misery perfusion in the cerebral hemisphere with chronic unilateral major cerebral artery steno-occlusive disease using crossed cerebellar hypoperfusion: comparison of brain SPECT and PET imaging.

机构信息

Department of Neurosurgery, Iwate Medical University, 19-1 Uchimaru, Morioka, 020-8505, Japan.

出版信息

Eur J Nucl Med Mol Imaging. 2013 Oct;40(10):1573-81. doi: 10.1007/s00259-013-2463-2. Epub 2013 Jun 6.

Abstract

PURPOSE

In patients with unilateral internal carotid or middle cerebral artery (ICA or MCA) occlusive disease, the degree of crossed cerebellar hypoperfusion that is evident within a few months after the onset of stroke may reflect cerebral metabolic rate of oxygen in the affected cerebral hemisphere relative to that in the contralateral cerebral hemisphere. The aim of the present study was to determine whether the ratio of blood flow asymmetry in the cerebellar hemisphere to blood flow asymmetry in the cerebral hemisphere on positron emission tomography (PET) and single photon emission computed tomography (SPECT) correlates with oxygen extraction fraction (OEF) asymmetry in the cerebral hemisphere on PET in patients with chronic unilateral ICA or MCA occlusive disease and whether this blood flow ratio on SPECT detects misery perfusion in the affected cerebral hemisphere in such patients.

METHODS

Brain blood flow and OEF were assessed using (15)O-PET and N-isopropyl-p-[(123)I]iodoamphetamine ((123)I-IMP) SPECT, respectively. All images were anatomically standardized using SPM2. A region of interest (ROI) was automatically placed in the bilateral MCA territories and in the bilateral cerebellar hemispheres using a three-dimensional stereotaxic ROI template, and affected-to-contralateral asymmetry in the MCA territory or contralateral-to-affected asymmetry in the cerebellar hemisphere was calculated. Sixty-three patients with reduced blood flow in the affected cerebral hemisphere on (123)I-IMP SPECT were enrolled in this study.

RESULTS

A significant correlation was observed between MCA ROI asymmetry of PET OEF and the ratio of cerebellar hemisphere asymmetry of blood flow to MCA ROI asymmetry of blood flow on PET (r = 0.381, p = 0.0019) or SPECT (r = 0.459, p = 0.0001). The correlation coefficient was higher when reanalyzed in a subgroup of 43 patients undergoing a PET study within 3 months after the last ischemic event (r = 0.541, p = 0.0001 for PET; r = 0.609, p < 0.0001 for SPECT). The blood flow ratio on brain perfusion SPECT in all patients provided 100 % sensitivity and 58 % specificity, with 43 % positive and 100 % negative predictive values for detecting abnormally elevated MCA ROI asymmetry of PET OEF.

CONCLUSION

The ratio of blood flow asymmetry in the cerebellar hemisphere to blood flow asymmetry in the cerebral hemisphere on PET and SPECT correlates with PET OEF asymmetry in the cerebral hemisphere, and this blood flow ratio on SPECT detects misery perfusion in the affected cerebral hemisphere.

摘要

目的

在单侧颈内动脉或大脑中动脉(ICA 或 MCA)闭塞性疾病患者中,卒中发作后数月内出现的小脑交叉灌注不足程度可能反映了受累半球的脑氧代谢率与对侧半球的脑氧代谢率之比。本研究旨在确定慢性单侧 ICA 或 MCA 闭塞性疾病患者正电子发射断层扫描(PET)和单光子发射计算机断层扫描(SPECT)小脑半球血流不对称与脑半球氧摄取分数(OEF)不对称的比值是否与 PET 检测到的 MCA 区域不对称性相关,并确定 SPECT 检测到 MCA 区域不对称性。

方法

分别使用 15O-PET 和 N-异丙基-p-[(123)I]碘代苯丙胺(123I-IMP)SPECT 评估脑血流和 OEF。所有图像均使用 SPM2 进行解剖标准化。使用三维立体定向 ROI 模板自动在双侧 MCA 区域和双侧小脑半球中放置 ROI,并计算 MCA 区域的受累侧-对侧不对称性或小脑半球的对侧-受累侧不对称性。本研究共纳入 63 例 123I-IMP SPECT 显示受累侧脑血流减少的患者。

结果

PET OEF 的 MCA ROI 不对称性与小脑半球血流不对称与 MCA ROI 血流不对称的比值之间存在显著相关性(r = 0.381,p = 0.0019)或 SPECT(r = 0.459,p = 0.0001)。在分析最近一次缺血事件后 3 个月内进行 PET 研究的 43 例患者的亚组时,相关系数更高(r = 0.541,p = 0.0001 用于 PET;r = 0.609,p < 0.0001 用于 SPECT)。所有患者的脑灌注 SPECT 血流比值均提供了 100%的敏感性和 58%的特异性,对 PET OEF 异常升高的 MCA ROI 不对称检测的阳性预测值为 43%,阴性预测值为 100%。

结论

PET 和 SPECT 小脑半球血流不对称与大脑半球血流不对称的比值与大脑半球 PET OEF 不对称相关,并且 SPECT 上的血流比值可检测到受累半球的低灌注。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5dc3/3779315/9b0093420523/259_2013_2463_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验