Department of Occupational Therapy, I-Shou University, Kaohsiung, Taiwan.
J Formos Med Assoc. 2013 Jun;112(6):332-7. doi: 10.1016/j.jfma.2012.02.023. Epub 2012 Jun 12.
BACKGROUND/PURPOSE: The Purdue pegboard test is widely used in measuring the hand dexterity of patients with schizophrenia. In patients with schizophrenia, the test-retest reliability and minimal detectable change (MDC) of this test remain largely unknown, limiting the interpretability of this popular measure. The purpose of this study was to estimate the test-retest reliability and the MDC of the Purdue pegboard test for patients with schizophrenia.
A total of 147 patients with schizophrenia participated in this study. The participants were administrated the five subtests of the Purdue pegboard test, three trials in a row at both of the two sessions 1 week apart. The intraclass correlation coefficient (ICC) was used to examine the test-retest reliability and the MDC was calculated on the basis of standard error of measurement.
The test-retest reliabilities of the five subtests were moderate to good (ICC = 0.73-0.88). The MDC (MDC%) was 3.0 (22.9%) for the dominant hand subtest, 3.1 (26.1%) for the nondominant hand subtest, 3.0 (31.7%) for the both hands subtest, 6.1 (17.7%) for the dominant + nondominant + both hands subtest, and 8.5 (35.3%) for the assembly subtest.
Our results reveal that the Purdue pegboard test has moderate-to-good test-retest reliability but substantial random measurement error. These findings should enable clinicians and researchers to monitor and interpret the changes in the hand dexterity of patients with schizophrenia more accurately and confidently.
背景/目的:普杜斯钉板测试广泛用于测量精神分裂症患者的手部灵巧度。在精神分裂症患者中,该测试的重测信度和最小可检测变化(MDC)在很大程度上尚不清楚,限制了这种流行测量方法的可解释性。本研究的目的是评估精神分裂症患者普杜斯钉板测试的重测信度和 MDC。
共有 147 名精神分裂症患者参与了这项研究。参与者连续三次在两个 1 周间隔的会议上进行普杜斯钉板测试的五个子测试。使用组内相关系数(ICC)来检查重测信度,根据测量误差的标准来计算 MDC。
五个子测试的重测信度为中等至良好(ICC=0.73-0.88)。MDC(MDC%)分别为:惯用手子测试为 3.0(22.9%),非惯用手子测试为 3.1(26.1%),双手子测试为 3.0(31.7%),惯用手+非惯用手+双手子测试为 6.1(17.7%),组装子测试为 8.5(35.3%)。
我们的结果表明,普杜斯钉板测试具有中等至良好的重测信度,但存在大量随机测量误差。这些发现应使临床医生和研究人员能够更准确和自信地监测和解释精神分裂症患者手部灵巧度的变化。