Suppr超能文献

专项耐力平板支撑测试评估整体核心肌肉功能。

Sport-specific endurance plank test for evaluation of global core muscle function.

机构信息

Dr. Stephen Hui Research Centre for Physical Recreation and Wellness, Department of Physical Education, Hong Kong Baptist University, Hong Kong, China.

Dr. Stephen Hui Research Centre for Physical Recreation and Wellness, Department of Physical Education, Hong Kong Baptist University, Hong Kong, China.

出版信息

Phys Ther Sport. 2014 Feb;15(1):58-63. doi: 10.1016/j.ptsp.2013.03.003. Epub 2013 Jul 11.

Abstract

OBJECTIVE

To examine the validity and reliability of a sports-specific endurance plank test for the evaluation of global core muscle function.

DESIGN

Repeated-measures study.

SETTING

Laboratory environment.

PARTICIPANTS

Twenty-eight male and eight female young athletes.

MAIN OUTCOME MEASURES

Surface electromyography (sEMG) of selected trunk flexors and extensors, and an intervention of pre-fatigue core workout were applied for test validation. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and the measurement bias ratio */÷ ratio limits of agreement (LOA) were calculated to assess reliability and measurement error.

RESULTS

Test validity was shown by the sEMG of selected core muscles, which indicated >50% increase in muscle activation during the test; and the definite discrimination of the ∼30% reduction in global core muscle endurance subsequent to a pre-fatigue core workout. For test-retest reliability, when the first attempt of three repeated trials was considered as familiarisation, the ICC was 0.99 (95% CI: 0.98-0.99), CV was 2.0 ± 1.56% and the measurement bias ratio */÷ ratio LOA was 0.99 */÷ 1.07.

CONCLUSION

The findings suggest that the sport-specific endurance plank test is a valid, reliable and practical method for assessing global core muscle endurance in athletes given that at least one familiarisation trial takes place prior to measurement.

摘要

目的

检验一种特定于运动的耐力平板测试评估整体核心肌肉功能的有效性和可靠性。

设计

重复测量研究。

环境

实验室环境。

参与者

28 名男性和 8 名女性年轻运动员。

主要观察指标

对选定的躯干屈肌和伸肌进行表面肌电图(sEMG)检测,并进行预疲劳核心训练干预,以验证测试的有效性。采用组内相关系数(ICC)、变异系数(CV)和测量偏差比“÷”比值的界限(LOA)来评估可靠性和测量误差。

结果

测试的有效性通过选定核心肌肉的 sEMG 显示,该测试表明在测试过程中肌肉激活度增加超过 50%;并且在进行预疲劳核心训练后,整体核心肌肉耐力明显下降了约 30%。对于测试-重测的可靠性,当将三次重复试验的第一次尝试视为熟悉阶段时,ICC 为 0.99(95%CI:0.98-0.99),CV 为 2.0±1.56%,测量偏差比“÷”比值 LOA 为 0.99“÷”1.07。

结论

研究结果表明,特定于运动的耐力平板测试是一种有效、可靠且实用的方法,可用于评估运动员的整体核心肌肉耐力,前提是至少进行一次熟悉化试验。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验