Okapi Sciences NV, B-3001 Heverlee, Belgium.
J Virol Methods. 2013 Nov;193(2):679-82. doi: 10.1016/j.jviromet.2013.07.034. Epub 2013 Jul 26.
Cyprinid herpesvirus-3 (CyHV-3) induces the highly contagious koi herpesvirus disease (KHVD) and may result in significant economic losses to the ornamental and food-producing carp industry. Suspicion of KHVD is triggered by clinical signs and confirmed using laboratory techniques. The latter are labour- and time-consuming, require specialised equipment and trained personnel. For rapid, on-site detection of CyHV-3, a lateral flow device (LFD) was developed using two monoclonal antibodies directed towards the viral glycoprotein ORF65. The LFD was highly specific with analytical and diagnostic specificities of 100%. Analytical sensitivity ranged between 1.25×10(2) and 2.40×10(4) plaque forming units per ml for isolates originating from geographically distinct regions. In experimentally infected carp, CyHV-3 was detected as early as 4-5 days post infection. Diagnostic sensitivities of 52.6% and 72.2% relative to PCR were recorded, depending on the viral isolate used. When onset of mortality was taken as reference, diagnostic sensitivities increased to 67.0% and 93.3%. The diagnostic sensitivity for freshly found-dead animals was 100%, irrespective of the virus isolate used. Given the high specificity and ease-of-use for on-site detection of CyHV-3, the LFD was regarded fit for purpose as a first-line diagnostic tool for the identification of acute CyHV-3 infections in KHVD affected (koi) carp.
鲤鱼疱疹病毒 3 型(CyHV-3)引发高度传染性的锦鲤疱疹病毒病(KHVD),可能给观赏鱼和食用鲤鱼产业造成巨大的经济损失。根据临床症状怀疑 KHVD,并用实验室技术进行确诊。后者既耗时又耗力,需要专门的设备和训练有素的人员。为了快速、现场检测 CyHV-3,开发了一种使用针对病毒糖蛋白 ORF65 的两种单克隆抗体的侧向流动设备(LFD)。LFD 具有高度特异性,分析特异性和诊断特异性均为 100%。分析灵敏度在 1.25×10(2)到 2.40×10(4)噬菌斑形成单位/毫升之间,针对来自不同地理区域的分离株。在实验感染的鲤鱼中,早在感染后 4-5 天即可检测到 CyHV-3。相对于 PCR 的诊断灵敏度分别为 52.6%和 72.2%,具体取决于所用的病毒分离株。当以死亡率开始为参考时,诊断灵敏度增加到 67.0%和 93.3%。对于新发现的死亡动物,诊断灵敏度为 100%,无论使用哪种病毒分离株。鉴于 LFD 具有高特异性和现场检测 CyHV-3 的易用性,它被认为是一种合适的一线诊断工具,可用于识别 KHVD 受影响(锦鲤)鲤鱼中的急性 CyHV-3 感染。