Suppr超能文献

角膜断层扫描参数和生物力学特征在圆锥角膜检测中的效能。

Efficacy of corneal tomography parameters and biomechanical characteristic in keratoconus detection.

机构信息

Refractive Errors Research Center, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Ophthalmology, Mashhad Medical University, Mashhad, Iran.

Refractive Errors Research Center, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Ophthalmology, Mashhad Medical University, Mashhad, Iran.

出版信息

Cont Lens Anterior Eye. 2014 Feb;37(1):26-30. doi: 10.1016/j.clae.2013.07.007. Epub 2013 Jul 30.

Abstract

AIM

To determine the efficacy of corneal thickness parameters and corneal biomechanical properties (CBPs) in discriminating between normal and keratoconus eyes.

METHOD

After performing a comprehensive ophthalmic examination, 50 mild to moderate keratoconus and 50 age and sex matched myopic astigmatism eyes were prospectively included in the study. The corneal topographic maps and CBP were obtained by Pentacam and Ocular response analyser, respectively. Central corneal thickness (CCT), thinnest corneal thickness (TCT), corneal thickness (CT) and percentage thickness increase (PTI) at 1, 3 and 5mm from the thinnest point and corneal volume (CV) at 3, 5, 7 and 10 centred on thinnest point, corneal hysteresis (CH) and corneal resistance factor (CRF) were recorded. Independent t-test and receiver operating characteristic (ROC) were done with SPSS software (version 15.0, SPSS, Inc.).

RESULTS

CCT, TCT, CT at 1, 3 and 5, CV at 3, 5, 7 and 10mm, CH and CRF were significantly lower in keratoconus eyes compared to controls (p<0.001). In addition, PTI at 1, 3 and 5mm from the thinnest point showed significantly higher values in keratoconus group. ROC analysis demonstrated good predictive accuracy for cut-off point values. However, the centrally located indices had higher predictive accuracy compared to the peripherally located indices.

CONCLUSION

Although good sensitivity and specificity were found for the mentioned parameters, the centrally located indices had higher predictive accuracy compared to peripherally located indices. It is suggested to use a combination of corneal pachymetry together with CBP for more accurate detection of keratoconus.

摘要

目的

确定角膜厚度参数和角膜生物力学特性(CBP)在区分正常眼和圆锥角膜眼中的疗效。

方法

对 50 例轻度至中度圆锥角膜和 50 例年龄和性别匹配的近视散光眼进行全面眼科检查后,前瞻性纳入本研究。使用 Pentacam 和 Ocular Response Analyzer 分别获得角膜地形图和 CBP。记录中央角膜厚度(CCT)、最薄角膜厚度(TCT)、角膜厚度(CT)和最薄点 1、3 和 5mm 处的厚度增加百分比(PTI)以及以最薄点为中心的角膜体积(CV)在 3、5、7 和 10mm 处、角膜滞后(CH)和角膜阻力因子(CRF)。使用 SPSS 软件(版本 15.0,SPSS 公司)进行独立 t 检验和受试者工作特征(ROC)分析。

结果

与对照组相比,圆锥角膜眼的 CCT、TCT、1、3 和 5mm 处 CT、3、5、7 和 10mm 处 CV、CH 和 CRF 明显降低(p<0.001)。此外,最薄点 1、3 和 5mm 处的 PTI 值在圆锥角膜组中显著升高。ROC 分析表明,临界值的预测准确性较好。然而,与周边指数相比,中央指数具有更高的预测准确性。

结论

虽然这些参数的敏感性和特异性都很好,但与周边指数相比,中央指数具有更高的预测准确性。建议使用角膜厚度测量与 CBP 相结合,以更准确地检测圆锥角膜。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验