To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.
Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (α = .05). Intraclass correlation measured the level of intraobserver agreement.
Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.
CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.
比较牙科石膏模型(DPM)和锥形束计算机断层扫描(CBCT)在牙弓测量中的应用,并研究CBCT图像伪影是否会影响此类测量的可靠性。
根据患者后牙是否存在金属修复体将20例患者分为两组。使用i-CAT CBCT设备对患者的双侧牙弓进行扫描,并获取DPM。两名检查者在CBCT图像和DPM上进行八项牙弓测量,并在15天后重复此操作。每组患者的牙弓测量结果分别采用Wilcoxon秩和(Mann-Whitney U)检验进行比较,显著性水平为5%(α = 0.05)。组内相关系数用于测量观察者内一致性水平。
牙齿健康的患者,所有DPM和CBCT牙弓测量结果之间无显著差异(P > 0.05)。有金属修复体的患者,大多数牙弓测量的DPM和CBCT结果之间存在显著差异(P > 0.05)。两名检查者对两种测量方法均表现出极好的观察者内一致性,组内相关系数高于0.95。
在牙弓测量中,CBCT与DPM具有相同的准确性,并受到图像伪影的负面影响。