Suppr超能文献

锥形束计算机断层扫描图像伪影对牙弓测量结果判定的影响。

Influence of cone-beam computed tomography image artifacts on the determination of dental arch measurements.

作者信息

Gamba Thiago O, Oliveira Matheus L, Flores Isadora L, Cruz Adriana D, Almeida Solange M, Haiter-Neto Francisco, Lopes Sérgio L P C

机构信息

a  PhD Student, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, São Paulo, SP, Brazil.

出版信息

Angle Orthod. 2014 Mar;84(2):274-8. doi: 10.2319/040313-255.1. Epub 2013 Aug 7.

Abstract

OBJECTIVE

To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.

MATERIALS AND METHODS

Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (α  =  .05). Intraclass correlation measured the level of intraobserver agreement.

RESULTS

Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.

CONCLUSION

CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.

摘要

目的

比较牙科石膏模型(DPM)和锥形束计算机断层扫描(CBCT)在牙弓测量中的应用,并研究CBCT图像伪影是否会影响此类测量的可靠性。

材料与方法

根据患者后牙是否存在金属修复体将20例患者分为两组。使用i-CAT CBCT设备对患者的双侧牙弓进行扫描,并获取DPM。两名检查者在CBCT图像和DPM上进行八项牙弓测量,并在15天后重复此操作。每组患者的牙弓测量结果分别采用Wilcoxon秩和(Mann-Whitney U)检验进行比较,显著性水平为5%(α = 0.05)。组内相关系数用于测量观察者内一致性水平。

结果

牙齿健康的患者,所有DPM和CBCT牙弓测量结果之间无显著差异(P > 0.05)。有金属修复体的患者,大多数牙弓测量的DPM和CBCT结果之间存在显著差异(P > 0.05)。两名检查者对两种测量方法均表现出极好的观察者内一致性,组内相关系数高于0.95。

结论

在牙弓测量中,CBCT与DPM具有相同的准确性,并受到图像伪影的负面影响。

相似文献

3
Reliability and accuracy of cone-beam computed tomography dental measurements.锥形束计算机断层扫描牙科测量的可靠性和准确性。
Am J Orthod Dentofacial Orthop. 2009 Jul;136(1):19-25; discussion 25-8. doi: 10.1016/j.ajodo.2007.09.016.
10
Diagnostic accuracy of impression-free digital models.无印模数字化模型的诊断准确性。
Am J Orthod Dentofacial Orthop. 2013 Dec;144(6):916-22. doi: 10.1016/j.ajodo.2013.04.024.

引用本文的文献

本文引用的文献

1
Influence of anatomical location on CT numbers in cone beam computed tomography.解剖位置对锥形束 CT 中 CT 数的影响。
Oral Surg Oral Med Oral Pathol Oral Radiol. 2013 Apr;115(4):558-64. doi: 10.1016/j.oooo.2013.01.021.
2
Cone beam CT in orthodontics: the current picture.正畸领域中的锥形束CT:现状
Int Orthod. 2013 Mar;11(1):1-20. doi: 10.1016/j.ortho.2012.12.011. Epub 2013 Feb 1.
7
Linear measurements using virtual study models.线性测量采用虚拟研究模型。
Angle Orthod. 2012 Nov;82(6):1098-106. doi: 10.2319/110311-681.1. Epub 2012 Apr 24.
8
Does the contact time of alginate with plaster cast influence its properties?藻酸盐与石膏绷带接触时间是否会影响其性能?
Braz Oral Res. 2012 May-Jun;26(3):197-201. doi: 10.1590/s1806-83242012005000005. Epub 2012 Mar 20.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验