四氟化钛和自酸蚀粘结系统对牙本质进行预处理对微拉伸粘结强度的影响。

Influence of dentin pretreatment with titanium tetrafluoride and self-etching adhesive systems on microtensile bond strength.

作者信息

Bridi Enrico Coser, Amaral Flávia Lucisano Botelho, França Fabiana Mantovani Gomes, Turssi Cecília Pedroso, Basting Roberta Tarkany

机构信息

School of Dentistry and Research Institute, São Leopoldo Mandic, Campinas, São Paulo, Brazil.

出版信息

Am J Dent. 2013 Jun;26(3):121-6.

Abstract

PURPOSE

To evaluate the effect of dentin pretreatment with 2.5% titanium tetrafluoride (TiF4) on microtensile bond strength (microTBS) of one- or two-step self-etching adhesive systems.

METHODS

24 human sound third molars were used. A flat dentin surface of each tooth was exposed. After planing, teeth were divided into groups so that dentin would be left untreated or treated with a 2.5% TiF4 solution for 1 minute. Specimens were then subdivided into two groups to receive one of the following adhesive systems: one-step self-etching Adper Easy One (ADP) or two-step self-etching adhesive Clearfil SE Bond (CLEAR). A block of composite measuring 5.0 mm high and 5.0 mm wide was made incrementally on the tooth. Specimens were taken to a metallographic cutter to fabricate sticks with a bond area of approximately 1 mm2. After 24 hours, specimens were submitted to microTBS testing and the failure mode was recorded by examining specimens under stereomicroscopy. Scanning electron microscope (SEM) photomicrographs were obtained of the tooth/restoration interface.

RESULTS

Two-way ANOVA and Tukey's test demonstrated that pretreatment of dentin with a TiF4 solution did not affect the microTBS values of either of the adhesive systems (P = 0.675). CLEAR provided higher bond strength than ADP, regardless of whether dentin was or was not pretreated with the TiF4 solution. Failure mode showed mostly adhesive failures in all groups, except when only ADP was used, causing mostly cohesive fractures in resin.

摘要

目的

评估用2.5%四氟化钛(TiF4)对牙本质进行预处理对一步或两步自酸蚀粘结系统微拉伸粘结强度(microTBS)的影响。

方法

使用24颗健康人第三磨牙。暴露每颗牙齿的平坦牙本质表面。刨平后,将牙齿分组,使牙本质不进行处理或用2.5% TiF4溶液处理1分钟。然后将标本再细分为两组,分别使用以下粘结系统之一:一步自酸蚀Adper Easy One(ADP)或两步自酸蚀粘结剂Clearfil SE Bond(CLEAR)。在牙齿上逐步制作一个高5.0毫米、宽5.0毫米的复合树脂块。将标本送至金相切割机制作粘结面积约为1平方毫米的小棒。24小时后,对标本进行微拉伸粘结强度测试,并通过立体显微镜检查标本记录失效模式。获取牙齿/修复体界面的扫描电子显微镜(SEM)显微照片。

结果

双向方差分析和Tukey检验表明,用TiF4溶液预处理牙本质对两种粘结系统的微拉伸粘结强度值均无影响(P = 0.675)。无论牙本质是否用TiF4溶液预处理,CLEAR的粘结强度均高于ADP。除仅使用ADP时主要导致树脂内聚性断裂外所有组的失效模式大多为粘结性失效