Suppr超能文献

全髋关节置换术中理想的股骨头大小平衡了稳定性和容积性磨损。

Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

机构信息

Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA.

出版信息

HSS J. 2012 Oct;8(3):270-4. doi: 10.1007/s11420-012-9287-7. Epub 2012 Sep 13.

Abstract

BACKGROUND

Over the last several years, a trend towards increasing femoral head size in total hip arthroplasty to improve stability and impingement free range of motion has been observed.

PURPOSE

The specific questions we sought to answer in our review were: (1) What are the potential advantages and disadvantages of metal-on-metal, ceramic-on-ceramic, and metal-on-polyethylene bearings? (2) What is effect that femoral head size has on joint kinematics? (3) What is the effect that large femoral heads have on bearing surface wear?

METHODS

A PubMed search and a review of 2012 Orthopaedic Research Society abstracts was performed and articles were chosen that directly answered components of the specific aims and that reported outcomes with contemporary implant designs or materials.

RESULTS

A review of the literature suggests that increasing femoral head size decreases the risk of postoperative dislocation and improves impingement free range of motion; however, volumetric wear increases with large femoral heads on polyethylene and increases corrosion of the stem in large metal-on-metal modular total hip arthroplasty (THA); however, the risk of potentially developing osteolysis or adverse reactions to metal debris respectively is still unknown. Further, the effect of large femoral heads with ceramic-on-ceramic THA is unclear, due to limited availability and published data.

CONCLUSIONS

Surgeons must balance the benefits of larger head size with the increased risk of volumetric wear when determining the appropriate head size for a given patient.

摘要

背景

在过去的几年中,髋关节置换术中股骨头尺寸增大以提高稳定性和无撞击运动范围的趋势一直在增加。

目的

我们在本次综述中试图回答的具体问题是:(1)金属对金属、陶瓷对陶瓷和金属对聚乙烯轴承的潜在优缺点是什么?(2)股骨头尺寸对关节运动学有什么影响?(3)大头股骨头对轴承表面磨损有什么影响?

方法

进行了 PubMed 搜索和对 2012 年骨科研究学会摘要的回顾,并选择了直接回答具体目标组成部分并报告了具有现代植入物设计或材料的结果的文章。

结果

对文献的回顾表明,增大股骨头尺寸可降低术后脱位的风险并改善无撞击运动范围;然而,大头股骨头会增加聚乙烯的容积磨损,并增加大金属对金属模块化全髋关节置换术(THA)中柄的腐蚀;然而,分别发展骨溶解或对金属碎屑不良反应的风险仍然未知。此外,由于可用数据有限,陶瓷对陶瓷 THA 中大股骨头的影响尚不清楚。

结论

外科医生在确定给定患者的合适股骨头尺寸时,必须权衡大头尺寸增大的益处与容积磨损增加的风险。

相似文献

1
Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.
HSS J. 2012 Oct;8(3):270-4. doi: 10.1007/s11420-012-9287-7. Epub 2012 Sep 13.
2
Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.
Clin Orthop Relat Res. 2016 Apr;474(4):985-94. doi: 10.1007/s11999-015-4683-1. Epub 2016 Feb 4.
3
Large Metal Heads and Highly Cross-Linked Polyethylene Provide Low Wear and Complications at 5-13 Years.
J Arthroplasty. 2018 Jul;33(7):2187-2191. doi: 10.1016/j.arth.2018.02.063. Epub 2018 Feb 23.
4
Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.
Clin Orthop Relat Res. 2016 Feb;474(2):365-71. doi: 10.1007/s11999-015-4319-5.
5
Head size in primary total hip arthroplasty.
EFORT Open Rev. 2018 May 21;3(5):225-231. doi: 10.1302/2058-5241.3.170061. eCollection 2018 May.
6
Femoral head diameter considerations for primary total hip arthroplasty.
Orthop Traumatol Surg Res. 2015 Feb;101(1 Suppl):S25-9. doi: 10.1016/j.otsr.2014.07.026. Epub 2015 Jan 14.
7
Wear Rates With Large Metal and Ceramic Heads on a Second Generation Highly Cross-Linked Polyethylene at Mean 6-Year Follow-Up.
J Arthroplasty. 2018 Feb;33(2):590-594. doi: 10.1016/j.arth.2017.09.006. Epub 2017 Sep 14.
8
Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
Clin Orthop Relat Res. 2015 Dec;473(12):3829-35. doi: 10.1007/s11999-015-4422-7.
9
Global diversity in bearings in primary THA.
EFORT Open Rev. 2020 Oct 26;5(10):763-775. doi: 10.1302/2058-5241.5.200002. eCollection 2020 Oct.
10
Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?
Clin Orthop Relat Res. 2011 Jun;469(6):1547-53. doi: 10.1007/s11999-010-1605-0.

引用本文的文献

1
Are Activity Restrictions Necessary After Total Hip Arthroplasty: A Systematic Review.
Arthroplast Today. 2024 Nov 13;30:101576. doi: 10.1016/j.artd.2024.101576. eCollection 2024 Dec.
2
Short-term outcomes with routine use of size ≥40 femoral heads in THA: A retrospective cohort study.
J Orthop. 2024 Aug 3;59:27-29. doi: 10.1016/j.jor.2024.08.001. eCollection 2025 Jan.
3
The Impact of Varying Femoral Head Length on Hip External Rotation During Posterior-approach Total Hip Arthroplasty.
Arthroplast Today. 2023 Jan 3;19:101072. doi: 10.1016/j.artd.2022.101072. eCollection 2023 Feb.
5
Impingement in total hip arthroplasty: A geometric model.
Proc Inst Mech Eng H. 2022 Feb 11;236(4):9544119211069472. doi: 10.1177/09544119211069472.
6
Recommendations for return to sports after total hip arthroplasty are becoming less restrictive as implants improve.
Arch Orthop Trauma Surg. 2021 Mar;141(3):497-507. doi: 10.1007/s00402-020-03691-1. Epub 2020 Dec 1.
7
Large Diameter Head in Primary Total Hip Arthroplasty: A Systematic Review.
Indian J Orthop. 2020 May 29;54(6):784-794. doi: 10.1007/s43465-020-00146-y. eCollection 2020 Nov.
8
Third-Generation Medium Cross-Linked Polyethylene Demonstrates Very Low Wear in Total Hip Arthroplasty.
Arthroplast Today. 2020 Jun 2;6(3):316-321. doi: 10.1016/j.artd.2020.04.006. eCollection 2020 Sep.
9
The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty.
Eur J Trauma Emerg Surg. 2021 Feb;47(1):211-216. doi: 10.1007/s00068-019-01222-1. Epub 2019 Sep 13.
10
Uncemented cups with and without screw holes in primary THA: a Swedish Hip Arthroplasty Register study with 22,725 hips.
Acta Orthop. 2019 Jun;90(3):258-263. doi: 10.1080/17453674.2019.1599777. Epub 2019 Apr 8.

本文引用的文献

2
Eight-year wear analysis in Longevity highly cross-linked polyethylene liners comparing 26- and 32-mm heads.
Arch Orthop Trauma Surg. 2011 Dec;131(12):1731-7. doi: 10.1007/s00402-011-1360-z. Epub 2011 Aug 5.
6
History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.
Clin Orthop Relat Res. 2011 Aug;469(8):2262-77. doi: 10.1007/s11999-011-1872-4.
7
Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?
Clin Orthop Relat Res. 2011 Jun;469(6):1547-53. doi: 10.1007/s11999-010-1605-0.
8
Dislocation after total hip arthroplasty with 28 and 32-mm femoral head.
J Orthop Traumatol. 2010 Jun;11(2):111-5. doi: 10.1007/s10195-010-0097-8. Epub 2010 May 27.
9
Risk factors for inflammatory pseudotumour formation following hip resurfacing.
J Bone Joint Surg Br. 2009 Dec;91(12):1566-74. doi: 10.1302/0301-620X.91B12.22287.
10
Wear and range of motion of different femoral head sizes.
J Arthroplasty. 2010 Sep;25(6):839-43. doi: 10.1016/j.arth.2009.07.007. Epub 2009 Sep 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验