Department of Radiology, Guy's and St Thomas' Hospital, London, UK.
Br J Radiol. 2013 Nov;86(1031):20120519. doi: 10.1259/bjr.20120519. Epub 2013 Oct 4.
This article reviews the technique, basic science principles and applications of integrated single photon emission CT (SPECT)-CT in musculoskeletal radiology. A review of the current evidence on the topic was undertaken, and selected clinical cases from the authors' institution have been used for illustration. SPECT-CT is a technology with emerging applications that offers technical advantages to image fusion of separately acquired SPECT and CT studies. The prevailing evidence indicates that there may be benefit in adding SPECT-CT to conventional imaging algorithms during the evaluation of some malignant and benign musculoskeletal conditions. SPECT-CT can improve both sensitivity and specificity by reducing equivocal interpretation in comparison to planar scintigraphy or SPECT alone. The evidence base for SPECT-CT in musculoskeletal radiology is still evolving. There is a lack of evidence comparing SPECT-CT with MRI in many key indications, and further research is required in these areas.
本文回顾了单光子发射 CT(SPECT)-CT 在肌肉骨骼放射学中的技术、基础科学原理和应用。对该主题的现有证据进行了综述,并使用作者所在机构的选定临床病例进行了说明。SPECT-CT 是一种具有新兴应用的技术,它为单独采集的 SPECT 和 CT 研究的图像融合提供了技术优势。目前的证据表明,在评估某些恶性和良性肌肉骨骼疾病时,将 SPECT-CT 添加到常规成像算法中可能会带来益处。与平面闪烁扫描或单独的 SPECT 相比,SPECT-CT 通过减少模棱两可的解释,可提高敏感性和特异性。SPECT-CT 在肌肉骨骼放射学中的证据基础仍在不断发展。在许多关键适应证中,SPECT-CT 与 MRI 的比较缺乏证据,这些领域需要进一步研究。